SINGLE STATION

SMOKE ALARM

For alarm models: 0945CA and 0946CA

Ionization sensing alarms may detect invisible fire
particles (associated with fast flaming fires) sooner
than photoelectric alarms. Photoelectric sensing
alarms may detect visible fire particles (associated
with slow smoldering fires) sooner than ionization
alarms. Home fires develop in different ways and are
often unpredictable. For maximum protection, Kidde
recommends that both Ionization and Photoelectric
alarms be installed.

 

Содержание 0945CA

Страница 1: ...ire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ioniz...

Страница 2: ...family are at stake Please take a few minutes to thoroughly read this alarm manual and save it for future reference Teach children how to respond to the alarms and that they should never play with th...

Страница 3: ...detect products of combustion using the ionization technique They contain 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858 01E Manufactured in comp...

Страница 4: ...room where someone sleeps with the door closed The closed door may prevent an alarm located outside from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizonta...

Страница 5: ...in 0 9 m 3 of the peak of the ceiling measured horizontally Image 2B Installation DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection Ionization Type Smoke Alarm with Hush Control or Photoelec...

Страница 6: ...noise may cause nuisance alarms Keep out of insect infested areas Avoid excessively dusty dirty or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may e...

Страница 7: ...K CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 10 cm 4 0 9 m 3 0 9 m 3 NOT IN THIS AREA ANYWHERE IN THIS AR...

Страница 8: ...ounted or horizontal when wall mounted Image 3A and 3B Drill a hole through the pencil marks and use the enclosed screws and anchors to secure the mounting plate Use a 3 16 drill bit for the screw anc...

Страница 9: ...Installation IMAGE 3A IMAGE 3C IMAGE 3D A LINE ALIGNMENT MARKS WALL MOUNTING POSITION ROTATE TO MOUNT OR TO REMOVE IMAGE 3B 8 IMAGE 3E BATTERY REMINDER TAB...

Страница 10: ...ng the alarm from the mounting plate With the blocks removed the tamper resist feature will be activated when the alarm is installed on the mounting plate The tamper resist tab will have to be release...

Страница 11: ...will sound the alarm if the electronic circuitry horn and battery are working If no alarm sounds the unit has a defective battery or other failure DO NOT use an open flame to test your alarm you could...

Страница 12: ...re is to be used only when a known alarm condition such as smoke from cooking activates the alarm If the alarm does sound check for fires first If a fire is discovered get out and call the fire depart...

Страница 13: ...particles of combustion and goes into alarm constant pulsating sound the red LED will flash once per second The flashing LED and pulsating alarm will continue until the air is cleared Red LED Hush mo...

Страница 14: ...NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a fire Test the alarm weekly to ensure proper operation Erratic or low sound coming from y...

Страница 15: ...cur about 10 seconds after the flash of the red LED indicator light Use only the following 9 V batteries for replacement Carbon Zinc Type Eveready 1222 Gold Peak 1604S Alkaline Type Energizer 522 Dura...

Страница 16: ...ing the unit After cleaning reinstall your alarm and test your alarm by using the Test button If cleaning does not restore the alarm to normal operation the alarm should be replaced Do not paint the u...

Страница 17: ...ization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated...

Страница 18: ...from each room Second story windows may need an escape ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your home where...

Страница 19: ...cted meeting place and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do s...

Страница 20: ...arms as shown in Image 1A and Image 1B The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the requi...

Страница 21: ...d after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsidiary corporations arisin...

Страница 22: ...2 1 Notes...