ACTIVATING THE ALARM
This model is equipped with a feature that automatically activates
the alarm when the alarm is mounted to the mounting bracket for
the first time. Once activated, the batteries will supply power to the
alarm for the life of the alarm (10 years). Be sure that the mounting
bracket is mounted correctly before installing the alarm on the
mounting bracket.
1. To activate the alarm, install the alarm on the mounting bracket (Figure 6) and rotate
the alarm clockwise (as indicated on the alarm cover) until the alarm ratchets into
place (the ratcheting function allows for aesthetic alignment). NOTE: The alarm will
mount to the bracket in four (4) positions (every 90 degrees).
This smoke alarm is equipped with a flashing red indicator light.The red LED will flash
every 40-45 seconds in the standby mode signifying that the alarm is receiving power.
The alarm is now activated!
2. After installation/activation, test your alarm by depressing and holding down the test
button for a minimum of 5 seconds (or until the alarm sounds). This should sound
the alarm.
CAUTION: Due to the loudness (85 decibels) of the alarm, always
stand an arms length away from the unit when testing.
4.TESTING
Test by pushing the test button on the cover and holding it down for a minimum of 5
seconds (or until the alarm sounds). This will sound the alarm if the electronic circuitry,
horn, and batteries are working. If no alarm sounds, the unit has defective batteries or
other failure. Erratic or low sound coming from the alarm may indicate a defective
alarm, and it should be returned for service. DO NOT use an open flame to test the
alarm, you could damage the alarm or ignite combustible materials and start a structure
fire.
5. KIDDE RECOMMENDATIONS
Smoke alarms shall be installed outside each separate sleeping area in the immediate
vicinity of the sleeping rooms and on each additional story of the family living unit,
including basements and excluding crawl spaces and unfinished attics. In new
construction, a smoke alarm also shall be installed in each sleeping room.
6. SERVICE AND WARRANTY
If after reviewing this manual you feel that your smoke alarm is defective in any way, do
not tamper with the unit. Return it for servicing to: Kidde Safety Europe,, Mathisen
Way, Colnbrook, Slough, Berkshire SL3 OHB. (See Warranty for in-warranty returns).
0910-7207-03_R1.qxd:_ 2009.8.13 6:52 PM Page 5