17
SX .4 Series Amplifiers
Opera
tion
SICK BAY
- cont
7c.)
PINK NOISE
is a built in pink noise generator
to test operation of the amplifier
Use the
UP
and
DOWN
keys to select
NOISE ON
or
NOISE OFf
.
When the PINK NOISE is ON
the
LEFT
and
RIGHT
indicators
in the
ISIS
VFD will blink on
and off.
When you are done using the
PINK NOISE generator press the
ESC
key to return to the SICK
BAY menu.
NOTE...
If you exit the SICK BAY menu with the PINK NOISE generator
still on, the
LEFT
and
RIGHT
ISIS
VFD indicators will remain
blinking as a reminder.
HOME
ENT
ESC
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT
noise on
HOME
ENT
ESC
8.)
Amp Name
- Here you can assign a unique name to
your KICKER SX amplifier. This name will replace the model
name in the DEFAULT screen. If you change your mind and
do not want to change the name, press and hold the
HOME
key for 1.5 seconds BEFORE making any changes.
The
ESC
and
ENT
keys move
the cursor left or right to select
which character to change.
Use the
UP
and
DOWN
keys to
change the character displayed
(A, B, C...1, 2, 3...etc)
When you are finished press and
hold the
HOME
key for 1.5
seconds to save your new
amplifier name.
HOME
ENT
ESC
HOME
ENT
ESC
HOME
ENT
ESC
PRESS &
HOLD
16
SX .4 Series Amplifiers
Opera
tion
SYSTEM
MENU
- This menu item contains many diagnostic
tools and first time setup options. Use the
UP
and
DOWN
arrow keys to scroll through the options and press
ENT
to
select. Press the
ESC
key to return to the SYSTEM menu.
1.)
Volt Now
- Displays the current voltage at the
ampl12 volt terminal.
2.)
Volt Min
- Displays the lowest voltage seen at the
ampl12 volt terminal since being installed.
3.)
Volt Max
- Displays the highest voltage at the
ampl12 volt terminal since being installed.
4.)
Temp Now
- Displays the current temperature of
the amplifier.
5.)
Temp Max
- Displays the highest temperature the
amplifier has reached since being installed.
6.)
Run Time
- Displays the total time the amplifier
has been powered up since installation in 1/10th of
an hour increments
7.)
Sick Bay
- Contains several
diagnostic tools. Once in this menu
you use the
UP
and
DOWN
keys to
scroll through
CURRENT
,
HISTORY
and
PINK NOISE
options. Press the
ENT
key to select.
7a.)
CURRENT
shows amplifiers current status or fault
code. The 6 possible codes are:
normal
- No problem, normal operation.
thermal
- Thermal cutoff protection engaged.
short
- Short circuit protection engaged.
Hi-Volt
- High voltage protection engaged.
FUSE
- Faulty or blown power fuse.
SERVICE
- Amp requires service by KICKER.
When you are done viewing
the current status press the
ESC
key to return to the SICK
BAY menu.
7b. )
HISTORY
logs the last 5 fault codes and how
long ago they happened when
compared to the RUN TIME log.
Use the
UP
and
DOWN
keys to select the
HISTORY
log
entry you want to view.
Press and hold the
ENT
key
to view the time it happened.
When you are done viewing
the history press the
ESC
key.
HOME
ENT
ESC
HOME
ENT
ESC
HOME
ENT
ESC
HOME
ENT
ESC
HOME
ENT
ESC