CHARGING STAGE PROFILE
BULK
ABSORPTION
FLOAT
PULSE
CONSTANT CURRENT UP TO
GEL
100%
Current
Until
14.1 V
CONSTANT CURRENT DROP TO 3.8A
AGM
100%
Current
Until
14.4 V
WET
100%
Current
Until
14.7 V
CALCIUM
100%
Current
Until
15.4 V
LITHIUM
100%
Current
Until
14.4 V
Constant
14.1 V
Constant
14.4 V
Constant
14.7 V
Constant
15.4 V
Constant
14.7 V
13.7V at 100% Current
Restarts Absorption when voltage drops to 12.6V
BULK
BULK
CHOOSING THE BATTERY TYPE
The default battery setting is
AGM
.
When the auxiliary battery is connected, press the and hold the mode button for 5
seconds or until the battery light starts flashing then select from either
GEL, AGM, WET,
CALCIUM or LITHIUM
and wait for the battery light to stop flashing your selection will
now be saved.
1
2
3
4
MODE
BATTERY TYPE
WET
GEL
AGM
CALCIUM
LITHIUM
BULK
ABSORPTION
FLOAT
PULSE
SOLAR
ALTERNATOR
CHARGING
12V 25A DC 4-STAGE
11
NOTE: When in float stage battery is fully charged.
When its in pulse stage battery is fully charged and maintained.