4
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Toggle
®
Tables - Dual Motor Height-Adjustable Base, Model EL
Assembly Instructions
Figure 5 - Centered Wire Trough with Control Box Between Cross-Tube Assembly
#10 x / ”
pan head
screw
5
8
wire
trough
tabletop
cross-tube
assembly
control
box
power
cord
key
pad cord
(optional)
leg control
cord (short)
leg control
cord (long)
Wire Trough (Optional)
Note:
The wire trough is an
accessory that must be ordered
separately.
Note:
Control cables can be
routed differently than shown.
The control box can be mounted
to the underside of tabletops
24” in depth at one location,
between the cross-tube
assembly (Figure 5). Control
boxes mounting under tabletops
30” or 36” in depth can
mount in one of five mounting
locations, one being the same
as the control box mounted
between the cross-tube
assembly on 24” tabletops
(Figure 5). If the control box is
mounted between the cross-tube
assembly, reference Figure 5 for
placement of the wire trough.
A 30” or 36” depth tabletop
is the only depth which will
allow a control box to be in
the following locations. If the
control box is mounted to the
front user side of the table,
reference Figure 6. Mounting
to the front of the table does
not require the use of the
“optional key pad” (Figure 6).
If the control box is mounted
behind the cross-tube assembly,
reference Figure 7.
9. Align the wire trough holes to
the appropriate holes in the
tabletop. Using six #10 x
5
/
8
”
pan head screws, secure the
wire trough to the tabletop as
illustrated (Figure 5, 6, & 7).
10. With help from another person,
carefully turn table to the upright
position. Adjust glides on feet to
level the table. Plug the power
cord into a grounded outlet power
source (Detail D).
Note:
Power
cord must have enough slack so
the table can cycle through its
entire range of motion.
11.
The table must be “zero
set” prior to being placed
into service. Refer to table
“zero setting” instructions
in the trouble shooting
guide on page 8.
12. If the table is not operating
properly, see the trouble
shooting guide in this
instruction.
This product is for use on a nominal 120-volt circuit and has a grounding plug
that looks like the plug illustrated in Detail D. Make sure that the product is
connected to an outlet having the same configuration as the plug. No adapter
should be used with this product.
GROUNDING INSTRUCTIONS
Detail D
grounding
pin
grounded
outlet
Figure 6 - Centered Wire Trough with Control Box Front User Side, 30” or 36” Table Depth
wire
trough
tabletop
cross-tube
assembly
control
box
power
cord
leg control
cord (short)
leg control
cord (long)