background image

2

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

Soltice

®

 Metal Multiple Seating - Reconfiguring Multiple Seating

Repair & Replacement Instructions

Note: 

The left- and right-hand side 

of each seating unit is determined 

when the user is facing the front of 

the unit as illustrated in Detail A. 

Note: 

Connecting table brackets are  

left- and right-handed as illustrated 

in Detail C. Brackets are pre-installed 

at the plant based on the original 

space-planning layout (Detail B). 

Brackets are very similar in 

appearance and if not installed 

to the proper left- or right-hand 

locations, tables will not install level. 

If possible, avoid removing and 

rearranging brackets. If rearranging 

brackets is necessary, take care 

and follow the instructions or 

disassembly and reassembly will be 

required. 

 

4. If connecting table brackets need 

to be rearranged, carefully lay the 

affected multiple seating units onto a 

soft, protective surface on their  

back-side. 

Caution:

 the assistance 

of a second person is required to 

lay seating units onto their backs 

that exceeds three seating positions 

(Figure 3). 

Note: 

Do not completely remove the 

seat mounting screws, as this will 

make the chair unstable and very 

difficult to reassemble properly. Do 

not loosen both sides of the seat at 

the same time. Assemble one table 

bracket at a time. 

5. Using a Phillips screwdriver, remove 

the four #10 x 

3

/

4

” wood screws 

securing the connecting table bracket 

to the seating unit, then loosen the 

front and back seat screws which 

hold the seat bottom to the frame. 

Twist the seat screws counter-

clockwise, only two full rotations 

(Figure 3 & Detail D). 

6. Remove the connecting table bracket 

between the seat cushion and arm 

stringer rail. Then, re-tighten the seat 

screws that were loosened in step 5 

(Figure 3). 

7. Repeat steps 5 and 6 to remove all 

connecting table brackets that need 

to be re-arranged.  

left

hand

right

hand

Detail A - Front View

Figure 3

connecting

table bracket

(right hand shown)

#10 x  / ”

Phillips wood

screws

3

4

seat

screw

connecting

table bracket

(left hand shown)

left

hand

right

hand

Detail B - Bottom View (brackets shown)

Detail C - Connecting Table Bracket Back View

connecting

table bracket

(left hand)

connecting

table bracket

(right hand)

larger

gap

larger

gap

seat

screw

seat

screw

connecting

table bracket

(right hand shown)

arm

stringer rail

Detail D

#10 x  / ”

Phillips wood

screws

3

4

Отзывы: