Keystone KSTAD957PA Скачать руководство пользователя страница 5

4

4

5

5

CONTROL PADS ON THE DEHUMIDIFIER

Control pads

When you push the button to change
operation modes, the unit will make 
a beep sound to indicate that it is 
changing modes.

NOTE:

 The control panel of the unit you purchased may be slightly different according to the 

models. 

Fig.1

7

7

Humidity Set Control Pads

8

8

: Down/Up Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.

The humidity level can be set within a range of 
35%RH(Relative Humidity) to 85%RH(Relative 
Humidity) in 5% increments.
For drier air, press the      pad and set to a lower 
percent value(%). 
For damper air, press the      pad and set  a higher 
percent value(%).

CONTROL PADS ON THE DEHUMIDIFIER

Other features 

Bucket Full Light

Glows when the bucket  is ready to be 
emptied.

When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue 
to run until the frost disappears.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart 
opertation in the first 3 minutes. This is to protect 
the unit. Operation will automatically start after 
3 minutes.

Setting the Timer

 When the unit is on, first  press the Timer 
 button,  the Timer Off indicator light 
 illuminates. It indicates the Auto Stop 
 program is initiated. Press it again the 
 Time On indecator light illuminates.It 
 indicates the Auto Start is initiated.
 

 Press or hold the UP or DOWN pad to 
 change the Auto time by 0.5 hour incre-
 ments,  up to 10 hours, then at 1 hour 
 increments up to 24 hours. The control  
 will count down the time remaining until 
 start. 
 The selected time will register in 5 seconds 
 and the system will automatically revert 
 back to display the previous humidity 
 setting.
 When the Auto start & Auto stop times are
 set, within the same program sequence, 
 TIMER ON OFF indicator lights illuminate 
  identifying both ON and OFF times are
  now programmed.
 Turning the unit ON or OFF at any time or 
 adjusting the timer setting to 0.0 will cancel
 the Auto Start/Stop function.
 When LED display window displays the
 code of  P2, the Auto Start/Stop function 
 will also be cancelled.

When the unit is off, first  press the Timer 

 button, the TIMER ON indicator light 
 illuminates. It indicates the Auto Start 
 program is initiated. Press it again the 
 Time Off indecator light illuminates.It 
 indicates the Auto Stop is initiated.

Check filter feature

The system starts to count the time once the fan 
motor operates. The check filter feature can be 
only activated when the accumulated operation 
time achieves 250 hours or more. The Reset 
 light(Clean filter indicator light) flashes at one time 
per second, after finishing clean the air filter, press 
the Filter pad and the Reset light(Clean filter indicator
light) goes off.  

11

11

Display

Shows the set % humidity level from 35% to 85% or auto 
start/stop time (0~24) while setting, then shows the actual
(

5% accuracy) room % humidity level in a range of 30%

RH(Relative Humidity) to 90%RH(Relative Humidity).

Error Codes and Protection Code:
AS

- Humidity sensor error--Unplug the unit and plug it back

       in. If error repeats, call for service.

Auto Shut Off

The dehumidifier shuts off  when the bucket  is 
full, or when the bucket is removed or not replaced 
in the proper position.When the setting humidity is 
reached, the unit will be shut off automatically. 
For some models,the fan motor will continue 
operating.

Auto-Restart

If the unit breaks off unexpectedly due to the power cut, 
it will restart with the previous function setting automa-
tically when the power resumes.

1

1

PUMP  Pad(on some models)

Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated.
When the bucket is full,the pump starts to work.Refer 
to the next pages for removing the collected water. 
Do not use this operation when the outdoor temperature

O

O

is equel to or less than 0 C (32 F).
 

6

6

POWER Pad

Press to turn the dehumidifier on and off.

9

9

TIMER Pad

Press to initiate the Auto start and Auto stop feature, 
in conjuction with the       and         pads.

E3

- Unit malfunction-- Unplug the unit and plug it back in. If 

      error repeats, call for service.

Eb

- Bucket is removed or not in right position-- Replace the 

       bucket in the right position.

3

3

Auto defrost operation on
indicator light

TIMER

1

1

6

6

5

5

4

4

Clean filter
indicator light 

Bucket full 
indicator light

Pump operation 
on indicator light

Continuous
operation on
indicator light

On
Off

Defrost

Full

CONT.

POWER

PUMP

COMFORT

FILTER

TURBO

ION

2

2

Timer on/off
indicator light

High fan 
indicator light

Ion operation
indicator light

Comfort dehumidifying
operation on 
indicator light

7

7

8

8

4

4

TURBO Pad

Control the fan speed. Press to select either High 
or Normal fan speed. Set the fan control to High for  
maximum moisture removal. When the humidity has 
been reduced and quiet operation is preferred, set 
the fan control to Normal.

3

3

 FILTER Pad

The check filter feature is a reminder to clean the 
Air Filter for more efficient operation. The Filter 
light(Clean filter l ight) will illuminate after 250 hours 
of operation. To reset after cleaning the filter, press 
the Filter pad and the light will go off.

Press to activate the comfort 

dehumidifying operation.

NOTE: On this operation,the unit can not be set 
humidity level. 

2

2

 COMFORT Pad(optional)

10

10

9

9

11

11

5

5

ION Pad(optional)

Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.

 CONTINUE Pad

Press to activate the c

ontinuous dehumidifying operation.

ES

- Temperature sensor error-- Unplug the unit and plug it 

       back in. If error repeats, call for service.

P2

- Bucket is full -- Empty the bucket.

10

10

Содержание KSTAD957PA

Страница 1: ...ency or manufacturer for details CD034IU DL 16120100000055 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacture...

Страница 2: ...Producto 1 866 646 4332 1 866 646 4332 MIDEA AMERICA CORPORATION PRODUCT REGISTRATION CENTER 11800 NW 100 ROAD STE 4 MEDLEY FL 33178 1037...

Страница 3: ...roperly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of trouble...

Страница 4: ...NS Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take...

Страница 5: ...rom 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection...

Страница 6: ...ttom of unit Casters can move freely Do not force casters to move over carpet nor move the unit with water in the bucket The unit may tip over and spill water Adehumidifier operating in a basement wil...

Страница 7: ...secure so there are no leaks Direct the hose toward the drain making sure that there are no kinks that will stop the warter flowing Place the end of the hose into the drain and make sure the end of th...

Страница 8: ...pump Check the pump hose does not link or block Empty the water of the bucket 3 Clean the air filter Remove the filter every two weeks based on normal operating conditions To remove the filter pull fi...

Страница 9: ......

Страница 10: ...Modelo KSTAD957PA DESHUMEDECEDOR MANUAL DE INSTRUCCI N Para un funcionamiento eficaz por favor lea las instrucciones cuidadosamente y gu rdelas en un lugar seguro para referencia futura...

Страница 11: ...mantener su aire acondicionado en buenas condiciones Un poco de cuidado de su parte puede ahorrarle mucho tiempo y dinero sobre la vida til de su aire acondicionado Encontrar muchas respuestas a prob...

Страница 12: ...EGURIDAD No cubra las aperturas de entrada o salida con trapos o toallas Una falta de flujo de aire puede causar recalentamiento e incendio Nunca coloque su dedo o cualquier otro objeto extra o en las...

Страница 13: ...uncionamiento se restablecer luego de los 3 minutos Caracter stica para verificar el filtro El sistema comienza a contar el tiempo una vez que el motor del ventilador comienza a funcionar La caracter...

Страница 14: ...alpicar agua Un deshumificador que funciona en un s tano no tendr efecto o ser peque o en secar un rea de almacenamientoadyacente continua tal como un armario a menos que exista una circulaci n de air...

Страница 15: ...ncionamiento de la bomba Cuando el recipiente se llena la bomba comienza a funcionar NOTA La bomba puede realizar mucho ruido cuando comienza a funcionar durante 3 a 5 minutos Es un fen meno normal As...

Страница 16: ...robar que la manguera de la bomba no se encuentre entrelazada o bloqueada Vac e el agua del recipiente 3 Limpiar el filtro de aire Retire el filtro de aire cada dos semanas si funciona en condiciones...

Страница 17: ......

Страница 18: ...Modelo KSTAD957PA DESHUMEDECEDOR MANUAL DE INSTRUCCI N Para un funcionamiento eficaz por favor lea las instrucciones cuidadosamente y gu rdelas en un lugar seguro para referencia futura...

Страница 19: ...mantener su aire acondicionado en buenas condiciones Un poco de cuidado de su parte puede ahorrarle mucho tiempo y dinero sobre la vida til de su aire acondicionado Encontrar muchas respuestas a prob...

Страница 20: ...EGURIDAD No cubra las aperturas de entrada o salida con trapos o toallas Una falta de flujo de aire puede causar recalentamiento e incendio Nunca coloque su dedo o cualquier otro objeto extra o en las...

Страница 21: ...uncionamiento se restablecer luego de los 3 minutos Caracter stica para verificar el filtro El sistema comienza a contar el tiempo una vez que el motor del ventilador comienza a funcionar La caracter...

Страница 22: ...alpicar agua Un deshumificador que funciona en un s tano no tendr efecto o ser peque o en secar un rea de almacenamientoadyacente continua tal como un armario a menos que exista una circulaci n de air...

Страница 23: ...ncionamiento de la bomba Cuando el recipiente se llena la bomba comienza a funcionar NOTA La bomba puede realizar mucho ruido cuando comienza a funcionar durante 3 a 5 minutos Es un fen meno normal As...

Страница 24: ...robar que la manguera de la bomba no se encuentre entrelazada o bloqueada Vac e el agua del recipiente 3 Limpiar el filtro de aire Retire el filtro de aire cada dos semanas si funciona en condiciones...

Страница 25: ......

Отзывы: