 34 

Getting Started
STEP 3. Install the Network Analyzer Modules

12.You have now completed the hardware installation procedure.

NOTE

Connect or disconnect the cable of the DUT to the test port 

3

Y9485-61603

M9340A B Out 1

Divider LO In

4

Y9485-61604

M9340A A Out 3

Divider Source In

5

Y9485-61605

M9340A A Out 2

Divider Source In

6

Y9485-61606

M9340A A Out 1

Divider Source In

7

Y9485-61617

M9340A B Out 3

Divider 100MHz In

8

Y9485-61618

M9340A B Out 2

Divider 100MHz In

9

Y9485-61619

M9340A B Out 1

Divider 100MHz In

h

M9485-61626

M9340A A In

M9340A A Out 2

i

M9485-61623

M9340A A Out 2

M9340A B In

j

M9485-61621

M9340A A In

M9309A RF/LO Out

k

M9485-61605

M9300A Out 5

M9309A 100MHz In

l

M9485-61606

M9300A Out 4

M9340A B In

m

M9485-61609

M9340A Sync

M9340A A Sync

n

M9485-61604

M9377A Trig

M9377A I/O2 Sync

No

Cable Part Numbers

Connection 1

Connection 2

Note

Содержание M9485A

Страница 1: ...89A PXIe Vector Network Analyzer Source M9309A PXIe Vector Network Analyzer Synthesizer M9340A PXIe Vector Network Analyzer RF Distributor M9376A PXIe Vector Network Analyzer Receiver M9377A PXIe Vect...

Страница 2: ...oftware described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the perf...

Страница 3: ...e Module Operating Conditions 9 Tools Required for the Installation Procedure 9 Installation Procedure 10 STEP 4 Install the Software 35 System Requirements 35 Hardware Requirements 35 Power Up the Co...

Страница 4: ...4 Contents...

Страница 5: ...etwork analyzer measurement just as the n port Network Analyzer The scope of this Startup Guide is to detail the processes of receiving and installing the network analyzer module and cables that compo...

Страница 6: ...fe work station to perform all work on electronic assemblies Figure 1 1 shows a static safe work station using two types of ESD protection conductive table mat and wrist strap combination and conducti...

Страница 7: ...Material Authorization RMA and return address For assistance finding Keysight contact information go to www keysight com find assist worldwide contact information for repair and service 3 Write the fo...

Страница 8: ...pment STEP 2 Check the Shipment The M9485A consists of several modules cables and dividers Use the Contents List in the shipping container to verify the completeness of your shipment If not complete r...

Страница 9: ...M9018A PCIe Cable Interface download the Keysight Multiple PXIe and AXIe Chassis System Configuration Tool Save the file to your local hard drive do not try to open the file from the Internet location...

Страница 10: ...3 on page 11 3 If the chassis has multiple fan speed settings ensure that the fan switch is set to high or auto 4 Position the chassis to provide ample space between the chassis fan intake and exhaust...

Страница 11: ...place To remove the module from the chassis you must first press the injector ejector handle to unlock it Figure 1 3 Installing the Network Analyzer Module 7 Repeat for other modules if present 8 Mod...

Страница 12: ...3 installations are explained in the following sections Standard Receiver M9376A Installation Module location for single chassis can be either one from the following two configuration for single chass...

Страница 13: ...either one from the following two configuration for two chassis Figure 1 6 on page 13 shows up to 24 port module on two chassis configuration with standard receiver modules M9376A Figure 1 7 on page 1...

Страница 14: ...lation Standard Receiver M9376A Installation on page 12 Configurable Test Set M9377A and M9378A Installation a The installation of the Configurable Test Set differs from installation of the Standard R...

Страница 15: ...te possible configuration for combination of Standard Receiver or Direct Access Receiver and Configurable Test Set In the tables 76A M9376A can be replaced with the M9377A if it is used as direct acce...

Страница 16: ...76A 76A 1 7 76A 76A 76A 77A 78A 76A 76A 76A 76A 1 9 76A 76A 76A 77A 78A 76A 76A 76A 76A 76A 76A 1 5 76A 76A 76A 76A 77A 78A 76A 1 7 76A 76A 76A 76A 77A 78A 76A 76A 76A 1 9 76A 76A 76A 76A 77A 78A 76A...

Страница 17: ...76A 76A 76A 76A 76A 2 4 76A 76A 76A 77A 78A 76A 77A 78A 2 6 76A 76A 76A 77A 78A 76A 77A 78A 76A 76A 2 8 76A 76A 76A 77A 78A 76A 77A 78A 76A 76A 76A 76A 2 6 76A 76A 76A 77A 78A 76A 76A 78A 77A 76A 2 8...

Страница 18: ...7A 76A 78A 77A 76A 76A 76A 78A 77A 76A 3 5 78A 77A 76A 76A 76A 76A 77A 78A 78A 77A 76A 3 5 76A 76A 76A 76A 78A 77A 77A 78A 78A 77A 76A 3 5 76A 76A 76A 76A 78A 77A 77A 78A 76A 77A 78A 3 5 76A 76A 76A 7...

Страница 19: ...lack plate cover should be removed 2 port module have the option of using M9376 60014 2 Way alignment plate c Next fasten the M9376 62006 4 way divider by ensuring that the SMP SMP adapter are fit wel...

Страница 20: ...ns Refer to Configurable Test Set M9377A and M9378A Installation on page 14 for the full combinations f Tighten the top mounting screw see callout 7 in Figure 1 3 and the bottom mounting screw located...

Страница 21: ...Install the Network Analyzer Modules Figure 1 11 Installing 4 Way Divider NOTE SMP SMP adapters are furnished with the divider at factory shipment Do not remove the SMP SMP adapters from dividers exce...

Страница 22: ...vider as shown in Figure 1 12 on page 22 below on the dividers The color in circle shows the color of the cable Figure 1 12 Label for Divider Figure 1 13 Cable Removal Tool part number 5002 3361 NOTE...

Страница 23: ...test port connector When connecting or disconnecting a cable for Device Under Test DUT to from test port first hold the connector saver body steady with 5 5 mm open end wrench to prevent the connecto...

Страница 24: ...e 12 port configuration as shown in Figure 1 16 on page 24 and for all 24 port configuration as shown in Figure 1 17 on page 25 regardless of the receiver modules settings c Figure 1 18 on page 25 sho...

Страница 25: ...nstall the Network Analyzer Modules Figure 1 17 Cable Connections Between Source Synthesizers Reference and Distributor for 24 port Configuration Figure 1 18 Cable Connections Between Standard Modules...

Страница 26: ...eratures Table 1 7 Part Numbers of Required Cables for Connection No Cable Part Numbers Cable Type Required Tool to Place the Cable 0 8120 5091 Flexible 1 M9485 61601 Flexible 8 in lbs Torque Wrench f...

Страница 27: ...gh Power measurement 11 M9485 61611 Semi rigid Socket and torque driver to be used with socket adapter set to 8 in lb not supplied 12 M9485 61612 Semi rigid 13 M9485 61613 Semi rigid 14 M9485 61614 Se...

Страница 28: ...of the M9377A Figure 1 20 Cable Connections For Standard Measurement Configuration c Figure 1 21 on page 28 below shows the cable connection for high power measurement Its important to ensure that te...

Страница 29: ...gurable Test Set measurement correct jumper cable has to be selected and connected between test ports Jumper cables for the Configurable Test Set comes with color coding to ease cable selection Figure...

Страница 30: ...or high gain measurement Figure 1 24 on page 29 i Connect the cables according to connector number as shown in Figure 1 25 on page 30 These are connections for both situations where coupler M9378A is...

Страница 31: ...work Analyzer Modules Example of 1 Chassis Setup with Configurable Test Set and Standard Receiver or Direct Access Receiver Figure 1 26 Cable Connection of 1 Chassis with Configurable Test Set and Sta...

Страница 32: ...s Example of 2 Chassis Setup with Configurable Test Set and Standard Receiver or Direct Access Receiver with 2 Way Divider Figure 1 27 Cable Connection of 2 Chassis with Configurable Test Set and Stan...

Страница 33: ...set of cables as shown in Table 1 8 on page 33 are required Table 1 8 Part Numbers of Required Cables for Connection No Cable Part Numbers Connection 1 Connection 2 Note a 1250 4189 M9340A B In is SMB...

Страница 34: ...Y9485 61606 M9340A A Out 1 Divider Source In 7 Y9485 61617 M9340A B Out 3 Divider 100MHz In 8 Y9485 61618 M9340A B Out 2 Divider 100MHz In 9 Y9485 61619 M9340A B Out 1 Divider 100MHz In h M9485 61626...

Страница 35: ...l PC connected to the chassis by a PCI to PXI interface is required Embedded controller Keysight M903xA or an equivalent embedded controller that meets the following requirements A PXIe system control...

Страница 36: ...to the Keysight M9018A documentation for further details 2 Connect peripherals mouse keyboard monitor 3 Power up the chassis Software Installation Overview The software installation includes the follo...

Страница 37: ...a remote controller install the PXIe Chassis Drivers a Using the downloadable file at http www keysight com find m9018a launch the installer b Follow the installer prompts 4 Complete the installation...

Страница 38: ...oftware NOTE When using two chassis power on the chassis first which does not have embedded controller or is not connected with remote controller the power on the chassis which has embedded controller...

Страница 39: ...in the help file The operator s check is not complete solution to find all malfunctions Hence perform the verification and performance tests to check the complete performance of M9485A Operator s che...

Страница 40: ...40 Getting Started STEP 5 Verify Operation of the Network Analyzer Modules...

Страница 41: ...odule Help System Use the Help System to quickly reference programming and user documentation To access Help From the analyzer module software On your PC screen click the Network Analyzer icon After m...

Страница 42: ...e available on the Web at www keysight com find assist If you do not have access to the Internet please contact your Keysight field engineer NOTE In any correspondence or telephone conversation refer...

Страница 43: ...This information is subject to change without notice Keysight Technologies 2015 2016 M9485 90010 www keysight com...

Отзывы: