Multichannel Overview
Multichannel Overview
The M9392A provides these multichannel capabilities:
l
Multichannel Wideband Signal Analysis
: Provides wide-band multichannel analysis capability by com-
bining two M9392A vector signal analyzers in one chassis.See "
Agilent 89600 Vector Signal Analysis Soft-
. The M9392A modules can be configured to use a common LO, or independent LOs. See
http://cp.literature.agilent.com/litweb/pdf/5991-0135EN.pdf
.
l
Multichannel Streaming
: Combines the M9392A’s multichannel capability with gapless recording to
address a wide variety of test needs in wireless communications and aerospace industries. Agilent’s
predefined packages have been tested to guarantee sustained data rates. These predefined mass storage
packages ensure performance when used with the recommended controller. See
http://cp.literature.agilent.com/litweb/pdf/5991-0221EN.pdf
.
Hardware and Software Requirements
l
Two M9392A Vector Signal Analyzers (full configuration) installed into one chassis. You have the option
of using two independent M9302A LO modules, or sharing one M9302A LO module. For details on these
configurations, see
http://cp.literature.agilent.com/litweb/pdf/5990-8254EN.pdf
o
(Optional) Agilent's predefined packages for streaming data storage have been tested to guarantee
sustained data rates. For details see
http://cp.literature.agilent.com/litweb/pdf/5990-9483EN.pdf
.
l
Agilent M9392A software version 1.2 or greater,and Agilent M9202A firmware version 512 or greater. If
you need to upgrade your system, install the latest software from the supplied CD or from the Drivers and
Software tab on the Technical Support page at
. If you intend to use mul-
tichannel streaming but have not performed a streaming upgrade, See "
l
Agilent IO Library Suite (IOLS) Version 16.3.16603.3 – see
http://www.agilent.com/find/iosuite
l
Agilent 89600 VSA software version 15.0 – see
http://www.agilent.com/find/VSA
Basic Steps to Using the M9392A Multichannel Capability
M9392A Soft Front Panel (SFP)
The M9392A SFP is used primarily to configure and control a complete Agilent M9392A PXI Vector Signal
Analyzer, or a single Agilent M9202A PXIe IF Digitizer in digitizer-only mode. It can only be used to control one
channel of M9392A or M9202A digitizer at any one time. It is possible to launch multiple running SFPs to control
multiple channels concurrently. However, the multichannel trigger capability cannot be controlled by way of the
SFP, so the SFP is not very useful when synchronized multichannel operation is required.
Configuration Assumptions
l
All software is installed – see "
.
l
All hardware is installed and cabled – see "
.
If are using a version of Agilent 89600 VSA software previous to release 15.0, do not use the pro-
cedure below. Instead, use the Connection procedure found in the M9392A SFP Help system. Open
the help system (
Programs > Agilent > M9392 > M9392 Help
) and navigate to the "Setting Up Mul-
tichannel Analysis" topic.
40
Agilent M9392A PXI Vector Signal Analyzer Startup Guide
Содержание M9392A
Страница 1: ...Startup Guide Keysight M9392A PXI Vector Signal Analyzer 50 MHz to 26 5 GHz...
Страница 2: ......
Страница 7: ......
Страница 8: ...Documentation Map Documentation Map Agilent M9392A PXI Vector Signal Analyzer Startup Guide 7...
Страница 40: ...Streaming Data Overview System diagram Agilent M9392A PXI Vector Signal Analyzer Startup Guide 39...
Страница 48: ......