background image

Textual conventions

The following table describes the typographical conventions used in this document.

Convention

Description

Boolean text

Words that represent Boolean notation are written in all uppercase text.

For example: 192.168.5.5 OR 10.20.30.30.

Keystrokes

Simultaneous keystrokes are shown by joining the key names with a plus
sign (+).

For example, CTRL+Q.

> (right angle
bracket)

Separates levels in a hierarchy of menu selections.

For example: “Select

Administration

>

Users

.”

About this guide

– 3 –

Содержание ixia Application Server

Страница 1: ...Application Server Release 9 10 Installation Guide Document version 202007160823 05 30 ...

Страница 2: ...rily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula or https support ixiacom com s upport services warranty license agreements The license set forth in the EULA represents the exclusive author...

Страница 3: ...N notice denotes a hazardous situation that if not avoided could result in minor or moderate injury A WARNING notice denotes a hazardous situation that if not avoided could result in death or serious injury iii ...

Страница 4: ...80 4939 6410 support ixiacom com Australia 61 742434942 support ixiacom com EMEA Support 40 21 301 5699 support emea ixiacom com Greater China Region 400 898 0598 support china ixiacom com Hong Kong 852 30084465 support ixiacom com India Office 91 80 4939 6410 support india ixiacom com Japan Head Office 81 3 5326 1980 support japan ixiacom com Korea Office 82 2 3461 0095 support korea ixiacom com ...

Страница 5: ...dd an account Click Accounts Other accounts Add an account Tap Accounts Other accounts Add an account To open the document in Outline view select View Outline To open the document in Outline view click View Outline To open the document in Outline view tap View Outline Select Protocols Click the Protocols tab Tap Protocols NA Double click the Client wizard Double tap the Client wizard Open the Pack...

Страница 6: ...te Regarding Ixia Applications 5 Supported Applications 5 Overview and Specifications 5 Installation and Setup 7 Overview 7 Unpacking the System 7 Preparing for Setup 7 Choosing a Setup Location 7 Rack Precautions 7 Installer Precautions 8 Rack Mounting Considerations 8 Ambient Operating Temperature 8 Reduced Airflow 8 Mechanical Loading 8 Circuit Overloading 8 Reliable Ground 8 vi ...

Страница 7: ...erview 13 Control Panel Buttons 13 Safety Precautions 14 Electrical 14 General Safety Precautions 15 ESD Precautions 15 Operating Precautions 15 Onboard Battery Replacement 15 Chapter 2 Ixia Application Server Settings 17 Remote Desktop Usage 17 Logging In to the Ixia Application Server 17 User Account Settings 17 Chapter 3 Running Ixia Applications 21 Configuration 21 Multi User Support 22 Known ...

Страница 8: ...INDEX 27 viii ...

Страница 9: ...This page intentionally left blank ix ...

Страница 10: ...ction explains the notational and typographical conventions used in this documentation and provides a list of related documentation Section contents Note icons and messages 2 Typographical conventions 2 Textual conventions 3 1 ...

Страница 11: ...names such as dialog boxes buttons menu selections and so forth l Command line interface commands and options l The name of a field option or parameter when used as part of an instruction For example Select the desired Inner Priority value Italic text Italic text indicates l A text reference to the name of a field option or parameter l Document and book titles l The first reference to a new term l...

Страница 12: ...ds that represent Boolean notation are written in all uppercase text For example 192 168 5 5 OR 10 20 30 30 Keystrokes Simultaneous keystrokes are shown by joining the key names with a plus sign For example CTRL Q right angle bracket Separates levels in a hierarchy of menu selections For example Select Administration Users About this guide 3 ...

Страница 13: ...This page intentionally left blank 4 ...

Страница 14: ...or later version l IxOS 5 70 EA SP2 Client or later version A downloadable version of the applications are available at www ixiacom com under Support Downloads Updates Overview and Specifications The Ixia Application Server is a high end dual processor 1U rack mount server with state of the art features It optimizes and enhances Ixia test application performance by running Ixia applications in a s...

Страница 15: ...tivity overheat warning and fan failure control panel also includes a main power button and a reset button Cooling System 6x high efficiency fans Physical Dimensions WxHxD 17 2 x 1 7 x 25 4 in 437 x 43 x 645 mm Weight 27 lbs 12 25 kg Shipping Weight 47 45 lbs 21 7 kg Operating Environment Up to 35 C 95 F maximum temperature is reduced by 1 C 300m 1 F 547 ft above 950m 3 117 ft Operating System Mic...

Страница 16: ...cation Server should include two sets of rail assemblies two rail mounting brackets and the mounting screws needed to install the system into the rack Read this section in its entirety before you begin the installation procedure outlined in the sections that follow Choosing a Setup Location l Leave enough clearance in front of the rack to allow you to open the front door completely 25 inches and a...

Страница 17: ...t in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced Airflow Mount equipment into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Mount equipment into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consider the connection of the equipment...

Страница 18: ...talling the Inner Rails Both the left and right side inner rails have been pre attached to the chassis shown in the following figure Figure Inner and Outer Rails Installing the Outer Rails To install the outer rails do the following 1 Measure the distance from the front rail from the front rail to the rear rail of the rack 2 Attach a short bracket to the front side of the right outer rail and a lo...

Страница 19: ... servicing Figure Installing the Inner and Outer Rails Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit The next step is to install the server into the rack To install the server into the rack do the following 1 Line up the rear of the chassis rails with the front of the rack rails 2 Slide the chassis rails into the rack rails keeping the...

Страница 20: ...extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it 3 Attach the two front brackets to each side of the chassis then the two rear brackets positioned with just enough space to accommodate the width of the telco rack 4 Finish by sliding the chassis into the rack and tightening the brackets ...

Страница 21: ... Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and power surges Note It is recommended that you use an uninterruptible power supply UPS System Interface Figure Front Panel Application Server Chapter 1 Ixia Application Server Installation 12 ...

Страница 22: ...on Reset Reboots the system Power Main power switch which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system Overheat Fan Fail When this LED flashes it indicates a fan failure When on continuously it indicates an overheat condition which may be caused by cables obstructing the airflow in...

Страница 23: ...move power from the system l Do not work alone when working with high voltage components l Power should always be disconnected from the system when removing or installing main system components such as the serverboard memory modules and floppy drive When disconnecting power you should first power down the system using the operating system and then unplug the power cords of all the power supply uni...

Страница 24: ...with electrical circuits or be pulled into a cooling fan l Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present l After accessing the inside of the chassis close it up and secure it to the rack after ensuring that all connections have ...

Страница 25: ... proper orientation of the onboard lithium battery There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarity Figure Onboard Battery Replacement Chapter 1 Ixia Application Server Installation 16 ...

Страница 26: ...o log in to the Ixia Application Server via remote desktop use the two Remote Desktop license cards pre installed with the application server To install additional RD CALs Client Access Licenses 1 Launch the RDS license manager and select Tools Terminal Services Remote Desktop Licensing Manager in Windows Server 2012 2 Select the server name and select Install Licences from the context menu 3 Sele...

Страница 27: ...s User Account passwords are based on the Chassis Serial Number For example if the Serial Number is 1UAC 123456 then the password is based on 123456 Table Single User Account Name Password Administrator 123456 Ixia 123456 Admin01 123456 01 User01 123456 01 Table Multi User Account Name Password Administrator 123456 Ixia 123456 Admin01 123456 01 Admin02 123456 02 Admin03 123456 03 Admin04 123456 04...

Страница 28: ...ame Password User02 123456 02 User03 123456 03 User04 123456 04 User05 123456 05 User06 123456 06 User07 123456 07 User08 123456 08 User09 123456 09 User10 123456 10 Chapter 2 Ixia Application Server Settings 19 ...

Страница 29: ...This page intentionally left blank 20 ...

Страница 30: ...ports multiple users simultaneously l Requires only a single Ixia test application installation on the application server instead of installing on all end user computers l Frees up the end user s computer l Supports disconnect reconnect from the test session in progress Configuration The Ixia chassis the Ixia Application Server and the end users computers are all connected via a corporate intranet...

Страница 31: ...rict each user to single session l Only one copy of the Ixia application needs to be installed by a user with an Administrator privilege Installation should be done via VNC not Remote Desktop l Each user will be able to execute an Ixia application by running a remote desktop session on the Ixia Application Server l Each user will be able to control and configure his her own instance of the Ixia ap...

Страница 32: ...ices Manager Figure Terminal Services Manager Figure Terminal Services Manager 2 Select RD Licensing Diagnoser The RD Licensing Diagnoser window appears Figure RD Licensing Diagnoser Select Connect to Remote Desktop Session Host Server to establish the remote desktop session Figure RD Licensing Diagnoser 3 After you select Connect to Remote Desktop Session Host Server the Select Computer dialog bo...

Страница 33: ...ers on the server IxNetwork IxNetwork is designed to support the Multi User function of the Microsoft Terminal Services The only limitations are the number of users and chassis supported by a single Application Server The Multi User Support configuration listed above Multi User Support is based on the following requirements l There are only 10 simultaneous users l Each user has 9 to 10 ports on av...

Страница 34: ...example user Admin01 log files will be stored in C Program Files Ixia IxNetwork admin01 data logs Default names and locations for trace logs are the same for all users so it is recommended to change the names when enabling IxAutomate The saved configuration for IxAutomate along with its log files and result files is saved in the same directory on the Ixia Application Server The config files for ea...

Страница 35: ...This page intentionally left blank 26 ...

Страница 36: ...Server 5 7 17 K keyboard interactions v known limitations 24 L limitations known 24 logging in 17 M mouse interactions v multi user support 22 N note 5 O overview and specifications 5 R rack mounting 8 remote desktop 17 running Ixia applications 21 S safety precautions 14 supported 5 T touch interactions v typographical conventions 2 U user account 17 27 ...

Страница 37: ...Ixia a Keysight Business 26601 West Agoura Road Calabasas California 91302 Keysight Technologies 2020 ...

Отзывы: