Keysight InfiniiMax III Series Probes
User’s Guide
7 Performance Plots
MX0109A and N2836A 26 GHz Solder-In Probe Heads (with N2803A)
N2838A/N5439A 25 GHz PCB ZIF Tip/Head (with N2803A)
N5440A/N5439A 28 GHz Ceramic ZIF Tip/Head (with N2803A)
N5447A/N5439A 28 GHz Ceramic High-Sensitivity ZIF Tip/Head (with N2803A)
N5441A 16 GHz Solder-In Head (with N2803A)
N5444A 30 GHz SMA 2.92 mm Head (with N2803A)
N5445A 30 GHz Browser Head, 1 mm span (with N2803A)
N5445A 30 GHz Browser Head, 2 mm span (with N2803A)
N5445A 30 GHz Browser Head, 3 mm span (with N2803A)
The performance plots in this chapter are for the N2803A 30 GHz probe amplifier with
various configurations InfiniiMax III probe heads. Items to note are:
• When InfiniiMax III probes are used with Keysight Infiniium 90000 X-Series
Oscilloscopes (and the Keysight DCA-X Wide-Bandwidth Sampling Scopes in some
cases), probe correction is applied to enhance the probe accuracy.
• Probe correction is computed from the s parameters of the various probe components
such as probe heads, probe amps, and accessories.
• Typically, the largest variation in a probe’s response is due to variation in the response
of the probe amplifier. For the InfiniiMax III probes, the s parameters of each probe
amplifier are measured at manufacture and stored in non-volatile memory in the probe
amplifier, thus allowing the removal of this component of variation.
• If care is taken in the manufacture of the probe heads and other accessories, the
variation in the probe response due to these components is minimal since they tend to
be simple passive devices. Therefore, the s parameters for probe heads and other
accessories are based on an average of a cross-section of parts. These nominal s
parameters are stored in the oscilloscopes firmware based on the model number of the
probe head or accessory and used in conjunction with the measured probe amplifiers s
parameters to compute the overall probe correction.
• Since InfiniiMax III probes can be used with instruments that do not apply probe
correction, the plots below show the response of a typical probe head and typical probe
amp with no probe correction (i.e. probe hardware only) as well as the response with
probe correction based on the nominal probe head s parameters and measured probe
amp s parameters.
• Measurement data used for these plots and for determining probe correction were
made using Keysight vector network analyzers swept to 40GHz and calibrated with
NIST traceable calibration standards.
Содержание InfiniiMax III N2800A Series
Страница 1: ...Keysight N2800A Series Differential InfiniiMax III Probes User s Guide...
Страница 22: ...22 InfiniiMax III Series Probes User s Guide 1 Using InfiniiMax III Series Probes...
Страница 47: ...InfiniiMax III Probe Heads 2 InfiniiMax III Series Probes User s Guide 47 Figure 41 Positioning Wires...
Страница 74: ...74 InfiniiMax III Series Probes User s Guide 4 Performance Specifications Characteristics...
Страница 92: ...92 InfiniiMax III Series Probes User s Guide 6 Performance Verification Figure 68 Probe Tips on Microstrip...
Страница 106: ...106 InfiniiMax III Series Probes User s Guide 6 Performance Verification...
Страница 110: ...110 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 111: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 111...
Страница 112: ...112 InfiniiMax III Series Probes User s Guide 7 Performance Plots N2838A N5439A 25 GHz PCB ZIF Tip Head with N2803A...
Страница 113: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 113...
Страница 114: ...114 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 115: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 115 N5440A N5439A 28 GHz Ceramic ZIF Tip Head with N2803A...
Страница 116: ...116 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 117: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 117...
Страница 119: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 119...
Страница 120: ...120 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 121: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 121 N5441A 16 GHz Solder In Head with N2803A...
Страница 122: ...122 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 123: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 123...
Страница 124: ...124 InfiniiMax III Series Probes User s Guide 7 Performance Plots N5444A 30 GHz SMA 2 92 mm Head with N2803A...
Страница 125: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 125 t...
Страница 126: ...126 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 127: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 127 N5445A 30 GHz Browser Head 1 mm span with N2803A...
Страница 128: ...128 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 129: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 129...
Страница 131: ...Performance Plots 7 InfiniiMax III Series Probes User s Guide 131...
Страница 132: ...132 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 134: ...134 InfiniiMax III Series Probes User s Guide 7 Performance Plots...
Страница 146: ...146 InfiniiMax III Series Probes User s Guide 8 SPICE Models...
Страница 148: ...148 InfiniiMax III Series Probes User s Guide Index...