6 List Sequence Measurements
View/Display
Preset
Performed on Preset.
Initial S/W Revision
Prior to A.02.00
Graticule
Pressing Graticule turns the display graticule On or Off. It also turns the graticule y-axis annotation on and
off.
Key Path
View/Display, Display
Remote Command
:DISPlay:WINDow[1]:TRACe:GRATicule:GRID[:STATe] OFF|ON|0|1
:DISPlay:WINDow[1]:TRACe:GRATicule:GRID[:STATe]?
Example
DISP:WIND:TRAC:GRAT:GRID OFF
Notes
The graticule is the set of horizontal and vertical lines that make up the grid/divisions for the x-axis
and y-axis.
Preset
On
State Saved
Saved in instrument state
Initial S/W Revision
Prior to A.02.00
System Display Settings
These settings are "Mode Global" – they affect all modes and measurements and are reset only by Restore
Misc Defaults or Restore System Defaults under System.
Key Path
View/Display, Display
Initial S/W Revision
Prior to A.02.00
Annotation Local Settings
This is a Mode Global override of the meas local annotation settings. When it is All Off, it forces
ScreenAnnotation, Meas Bar, Trace, and Active Function Values settings to be OFF for all measurements
in all modes. This provides the security based "annotation off" function of previous analyzers; hence it uses
the legacy SCPI command.
When it is All Off, the Screen, Meas Bar, Trace, and Active Function Values keys under the Display,
Annotation menu are grayed out and forced to Off. When Local Settings is selected, you are able to set the
local annotation settings on a measurement by measurement basis.
Key Path
View/Display, Display, System Display Settings
Remote Command
:DISPlay:WINDow[1]:ANNotation[:ALL] OFF|ON|0|1
:DISPlay:WINDow[1]:ANNotation[:ALL]?
Example
:DISP:WIND:ANN OFF
Sequence Analyzer User's & Programmer's Reference
653
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...