6 List Sequence Measurements
Source
Remote Command
:SOURce:FREQuency:CHANnels:NUMBer <int>
:SOURce:FREQuency:CHANnels:NUMBer?
Example
:SOUR:FREQ:CHAN:NUMB 1
Notes
This key is grayed out when the
is set to NONE.
This key is grayed out on E6630A.
Dependencies
This key is grayed out when the
is set to NONE.
This key is grayed out on E6630A.
Couplings
The channel number is coupled to the frequency value when the
is not
set to NONE. When the frequency value is changed, the channel number will increase or decrease to
match the new frequency. If the frequency is not at an exact match for a channel number, the nearest
channel number is displayed along with a greater than or less than sign to indicate the frequency is
above or below the channel number.
Preset
1
Min
Please refer to the tables below for the valid ranges.
Max
Please refer to the tables below for the valid ranges.
Initial S/W Revision
A.05.00
GSM/EDGE Channel Number Ranges
Band
Link (Device)
Range
Frequency (MHz)
P-GSM
Uplink (MS)
1 ≤ n ≤ 124
890.0 + 0.2*n
Downlink (BS)
1 ≤ n ≤ 124
935.0 + 0.2*n
E-GSM
Uplink (MS)
0 ≤ n ≤ 124
975 ≤ n ≤ 1023
890.0 + 0.2*n
890.0 + 0.2*(n–1024)
Downlink (BS)
0 ≤ n ≤ 124
975 ≤ n ≤ 1023
935.0 + 0.2*n
935.0 + 0.2*(n–1024)
DCS 1800
Uplink (MS)
512 ≤ n ≤ 885
1710.200 + 0.20*(n–512)
Downlink (BS)
512 ≤ n ≤ 885
1805.200 + 0.20*(n–512)
PCS 1900
Uplink (MS)
512 ≤ n ≤ 810
1850.200 + 0.2*(n–512)
Downlink (BS)
512 ≤ n ≤ 810
1930.200 + 0.2*(n–512)
R-GSM
Uplink (MS)
0 ≤ n ≤ 124
955 ≤ n ≤ 1023
890.0 + 0.2*n
890.0 + 0.2*(n–1024)
Downlink (BS)
0 ≤ n ≤ 124
955 ≤ n ≤ 1023
935.0 + 0.2*n
935.0 + 0.2*(n–1024)
GSM 450
Uplink (MS)
256 ≤ n ≤ 293
450.6 + 0.2*(n–259)
Downlink (BS)
256 ≤ n ≤ 293
460.6 + 0.2*(n–259)
GSM 480
Uplink (MS)
306 ≤ n ≤ 340
479.000 + 0.20*(n–306)
Downlink (BS)
306 ≤ n ≤ 340
489.000 + 0.20*(n–306)
GSM 850
Uplink (MS)
128 ≤ n ≤ 251
824.200 + 0.20*(n–128)
Sequence Analyzer User's & Programmer's Reference
519
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...