6 List Sequence Measurements
List Sequence Measurements
"Format Data: Byte Order (Remote Command Only)" on page 294
Initial S/W Revision
Prior to A.02.00
Measurement Group of Commands
Measure Commands:
:MEASure:<measurement>[n]?
This is a fast single-command way to make a measurement using the factory default instrument settings. These are the
settings and units that conform to the Mode Setup settings (e.g. radio standard) that you have currently selected.
•
Stops the current measurement (if any) and sets up the instrument for the specified measurement using the factory
defaults
•
Initiates the data acquisition for the measurement
•
Blocks other SCPI communication, waiting until the measurement is complete before returning results.
•
If the function does averaging, it is turned on and the number of averages is set to 10.
•
After the data is valid it returns the scalar results, or the trace data, for the specified measurement. The type of data
returned may be defined by an [n] value that is sent with the command.
•
The scalar measurement results will be returned if the optional [n] value is not included, or is set to 1. If the [n] value
is set to a value other than 1, the selected trace data results will be returned. See each command for details of what
types of scalar results or trace data results are available.
•
ASCII is the default format for the data output. (Older versions of Spectrum Analysis and Phase Noise mode
measurements only use ASCII.) The binary data formats should be used for handling large blocks of data since they
are smaller and faster than the ASCII format. Refer to the FORMat:DATA command for more information.
If you need to change some of the measurement parameters from the factory default settings you can set up the
measurement with the CONFigure command. Use the commands in the SENSe:<measurement> and
CALCulate:<measurement> subsystems to change the settings. Then you can use the READ? command to initiate the
measurement and query the results.
If you need to repeatedly make a given measurement with settings other than the factory defaults, you can use the
commands in the SENSe:<measurement> and CALCulate:<measurement> subsystems to set up the measurement.
Then use the READ? command to initiate the measurement and query results.
Measurement settings persist if you initiate a different measurement and then return to a previous one. Use
READ:<measurement>? if you want to use those persistent settings. If you want to go back to the default settings, use
270
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...