4 Mode Functions
Mode
:INSTrument:NSELect?
Example
:INST:NSEL 1
Notes
SA mode is 1
The command must be sequential: i.e. continued parsing of commands cannot proceed until the
instrument select is complete and the resultant SCPI trees are available.
Preset
Not affected by Preset. Set to default mode (1 for SA mode) following Restore System Defaults.
State Saved
Saved in instrument state
Initial S/W Revision
Prior to A.02.00
Application Mode Catalog Query (Remote Command Only)
Returns a string containing a comma separated list of names of all the installed and licensed measurement
modes (applications). These names can only be used with the :INSTrument[:SELect] command.
Remote
Comman
d
:INSTrument:CATalog?
Example
:INST:CAT?
Notes
Query returns a quoted string of the installed and licensed modes separated with a comma. Example:
"SA,PNOISE,WCDMA"
Backwards
Compatibil
ity Notes
VSA (E4406A) :INSTrument:CATalog? returned a list of installed INSTrument:SELECT items as a comma separated
list of string values:
"BASIC","GSM","EDGEGSM","CDMA","NADC","PDC","WCDMA","CDMA2K","CDMA1XEV","IDEN","WIDEN","WL
AN","SERVICE"
X-Series uses the ESA/PSA compatible query of a string contain comma separated values:
"SA,PNOISE,NFIGURE,BASIC,CDMA,CDMA2K,WCDMA,CDMA1XEV,EDGEGSM,GSM,NADC,PDC,TDSCDMA,DMOD
ULATION,WLAN"
Initial S/W
Revision
Prior to A.02.00
Application Identification (Remote Commands Only)
Each entry in the Mode Menu will have a Model Number and associated information: Version, and Options.
This information is displayed in the Show System screen. The corresponding SCPI remote commands are
defined here.
"Current Application Model " on page 136
"Current Application Revision" on page 137
"Current Application Options" on page 137
Current Application Model
Returns a string that is the Model Number of the currently selected application (mode).
136
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...