background image

1

General

Information

Introduction

The

purpose

of

this

manual

is

to

enable

you

to

use

your

16117C

Low

Noise

T

est

Lead

eciently

and

condently

.

This

manual

contains

both

general

and

specic

information.

T

o

use

the

16117C

to

perform

a

specic

function

(without

having

to

read

the

entire

manual),

follow

the

directions

in

\Using

the

16117C

".

Using

the

16117C

The

16117C

has

been

designed

to

operate

specically

with

the

4339B

High

Resistance

Meter

.

T

o

install

the

16117C,

turn

to

Chapter

2.

T

o

operate

the

16117C,

turn

to

Chapter

3.

T

o

order

replaceable

parts

for

the

16117C

,

turn

to

\Replaceable

P

arts"

in

Chapter

4.

Product

Description

The

16117C

has

been

designed

to

operate

specically

with

the

4339B

High

Resistance

Meter

.

The

16117C

is

used

to

measure

insulation

resistance

.

The

16117C

has

the

following

features:

Prepared

exclusive

connector

for

the

4339B .

This

allows

easy

to

make

original

test

xture

for

the

4339B

High-voltage

safety

designed

using

an

interlock

circuit

A

ccessories

Supplied

The

accessories

listed

in

T

able

1-1,

are

supplied

with

the

16117C:

T

able

1-1.

Furnished

A

ccessories

Description

P

art

Number

Quantity

Operation

and

Service

Manual

P/N

16117-90041

1

General

Information

1-1

Содержание 16117C

Страница 1: ...Keysight 16117C Low Noise Test Lead Operation and Service Manual...

Страница 2: ......

Страница 3: ......

Страница 4: ...ing charges duties and taxes for products returned to Agilent Technologies from another country Agilent Technologies warrants that its software and rmware designed by Agilent Technologies for use with...

Страница 5: ...mages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products If you...

Страница 6: ...ns and updates which are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated December 1991 First Edition February 1...

Страница 7: ...placement and internal adjustments must be made only by quali ed maintenance personnel Do not replace components with the power cable connected Under certain conditions dangerous voltages may exist ev...

Страница 8: ...ion sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in damage to or destruction of part or all of the...

Страница 9: ...Use Introduction 2 1 Initial Inspection 2 1 Ambient Environmental Considerations 2 3 Operating and Storage 2 3 Connecting the Adapter for Use 2 3 Packaging the Adapter 2 4 3 Operation Introduction 3 1...

Страница 10: ...1 3 2 Floating DUT Measurement Con guration 3 2 3 3 Interlock cable Assignment Wiring Side View 3 3 3 4 Example Con guration of Custom Test Fixture 3 5 Tables 1 1 Furnished Accessories 1 1 2 1 Content...

Страница 11: ...the 16117C turn to Chapter 3 To order replaceable parts for the 16117C turn to Replaceable Parts in Chapter 4 Product Description The 16117C has been designed to operate speci cally with the 4339B Hig...

Страница 12: ...ts against which the 16117C is tested When shipped from the factory the 16117C meets the speci cations listed in this section Applicable Test Voltage 1000 V maximum Applicable Test Current1 10 mA maxi...

Страница 13: ...hould be in perfect electrical condition Verify this by carefully performing an incoming inspection to check the adapter for signs of physical damage and missing contents If any discrepancy is found n...

Страница 14: ...ilent Part Number Quantity 1 Low Noise Test Lead 16117C 1 2 BNC Female Connector 1250 2317 1 3 Triaxial Female Connector 1250 2228 1 4 Operation and Service Manual1 16117 90041 1 1 Operation and Servi...

Страница 15: ...9B connection with 16117C has two con gurations oating and grounded DUT measurement con gurations The connections are di erent for each con guration The connections are as shown in Figure 2 2 and Figu...

Страница 16: ...ginal factory packaging materials Alteratively comparable packaging materials may be used Wrap the adapter in heavy paper and pack in anti static plastic packing material Use su cient shock absorbing...

Страница 17: ...h voltage BNC connector and is not compatible with standard BNC connectors 2 Triaxial cable The measured signal is carried on the center conductor of this connector 3 Interlock cable This connector en...

Страница 18: ...with the 16117C Figure 3 2 Floating DUT Measurement Con guration The BNC connector provides source voltage up to 1000 V A triaxial connector is used for the measured signal path The triaxial connector...

Страница 19: ...erlock cable has six lines The 4339B changes some settings Voltage Output Current Limit and Resistivity Mode depending on the interlock status Table 3 1 describes the role of each line Table 3 1 Pin A...

Страница 20: ...Limitation GND GND Open 16008B No Limitation GND Open GND 16117B Current Limit 0 5 mA GND Open Open 04339 65005 100 V maximum Current Limit 1 mA Open GND GND Not Applicable n a Not Used No Voltage out...

Страница 21: ...lose of this cover Figure 3 4 Example Con guration of Custom Test Fixture Center conductor of BNC connector and center conductor of triaxial connector is connected to contact of DUT A source voltage o...

Страница 22: ...d that operator can measure safely To keep safety condition you must execute following checking procedure periodically This procedure assumes your xture has top cover interlocing source voltage output...

Страница 23: ...Holder with Nuts 1 16117 87103 2 Warning Label Red on BNC and Triaxial cable 16117 87104 1 Label Yellow on Interlock cable 16117 61604 1 Cable Assembly Triaxial 2 16117 61605 1 Cable Assembly BNC 2 1...

Страница 24: ......

Страница 25: ...This information is subject to change without notice Keysight Technologies 2014 Edition 6 November 2014 16117 90041 16117 90041 www keysight com...

Отзывы: