1
Keysight ZA0060A Quick Start Guide
31
Test Steps and Description
Initialize Zigbee Radio
This test step initializes the Zigbee radio. The radio is closed after the completion of the step (and its
child steps).
– Instrument: The VISA address of the instrument will auto populate when the 34999 profile is selected.
Click Settings > Bench > Instruments to select the 34999 profile from the drop-down list.
– Device Type: Select to set the 34999B module as a Zigbee coordinator or router. The selection here
will load the appropriate firmware file in the RF module.
Initialize Zigbee Signaling
This test step must be a child step of
. This test step initializes the Zigbee signaling
mode.
– RF Path: Set the path of signaling operations to be either Downlink, Uplink or Dynamic (default).
– Downlink: Set the signal path from the DUT to the 34999B module.
– Uplink: Set the signal path from the 34999B module to the DUT.
– Dynamic: Set this path to enable the 34999B module to switch between uplink and downlink
dynamically based on the incoming or outgoing signal direction.