Keysight Technologies P9241A Скачать руководство пользователя страница 45

Applications Programming Interface (API) Overview

8

Keysight P9241/42/43A Oscilloscopes Startup Guide

45

 

5

To exit the Keysight Interactive IO application, choose 

Connect > Exit

 from the 

menu.

Using the SFP and the Remote API at the Same Time

In general, you can use the Soft Front Panel (SFP) and the remote applications 

programming interface (API) together, at the same time. This can be useful, for 

example, because it lets you change oscilloscope settings while debugging remote 

programs.

However, the SFP can become "locked out" while the oscilloscope waits for a 

waveform to become fully acquired. This can happen, for example, after these 

SCPI commands/queries: :WAVeform:DATA?, :WAVeform:PREamble?, 

:LISTer:DATA?, :SEARch:COUNt?, :DIGitize, or :SINGle. In these situations, you can 

clear the remote operation in progress by sending a Device Clear to the remote 

user interface.

Содержание P9241A

Страница 1: ...Keysight P9241 42 43A Oscilloscopes Startup Guide...

Страница 2: ...ense Agreement EULA a copy of which can be found at www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distrib...

Страница 3: ...pment Contents 13 4 Install the Software PC Requirements 15 Software Installation Overview 15 Updating Oscilloscope Firmware as New Oscilloscopes Are Connected 17 Updating Chassis Firmware 17 5 Connec...

Страница 4: ...SFP Interface 32 Access the Built In Quick Help 32 Select the User Interface Language 33 Recall the Default Oscilloscope Setup 33 Use Autoscale 34 Compensate Passive Probes 35 Turn On Measurements an...

Страница 5: ...Keysight P9241 42 43A Oscilloscopes Startup Guide 5 Measurement Category 50 Oscilloscope Measurement Category 50 Measurement Category Definitions 50 Product Markings 51 Index...

Страница 6: ...6 Keysight P9241 42 43A Oscilloscopes Startup Guide...

Страница 7: ...scope system as well as installing the required software If you have any questions after reviewing this information please contact your local Keysight Technologies representative or contact us through...

Страница 8: ...ng on page 41 Related Documentation To access documentation related to the Keysight P9241 42 43A oscilloscopes go to www keysight com manuals P9241A Document Description File name Format Startup Guide...

Страница 9: ...010 with the NET Framework to write IVI COM Console Applications in Visual C P924x_IVI_ProgrammingGuide pdf PDF IVI Driver reference help system Provides detailed documentation of the IVI COM and IVI...

Страница 10: ...10 Keysight P9241 42 43A Oscilloscopes Startup Guide 1 Introduction...

Страница 11: ...lies The following figure shows a static safe work station using two types of ESD protection conductive table mat and wriststrap combination and conductive floor mat and heelstrap combination Both typ...

Страница 12: ...x is not acceptable as a return address Instrument serial number s The serial number label is located on the bottom panel of the instrument The serial number can also be read from the Soft Front Panel...

Страница 13: ...nal AC DC Adapter Switching 90W 1 Output 15V 6A Level 6 Class 1 Safety 1 5061 7383 South Korean Class A EMC Declaration 1 5185 1605 Envelope Calibration Certificate 230 mm x 153 mm 1 5991 3402 End Use...

Страница 14: ...P9240CMPA Computer Serial Triggering and Analysis RS232 422 485 UART P9240ATOA Automotive Serial Triggering and Analysis CAN CAN dbc CAN FD LIN P9240SNSA SENT Single Edge Nibble Transmission Triggerin...

Страница 15: ...ont panel SFP device drivers IVI C IVI COM and LabVIEW G and documentation for the Keysight P9241 42 43A oscilloscopes Item Requirements Operating system Windows 7 64 bit or Windows 10 64 bit Processo...

Страница 16: ...d with your shipment and is also available at www keysight com products P9241A a Launch the software installer b Follow the installer prompts Choose a Complete installation to install all software and...

Страница 17: ...finiiVision Oscilloscope Update Keysight InfiniiVision Firmware Updating Chassis Firmware The software installation process on the host PC does not update chassis FPGA firmware If you should need to u...

Страница 18: ...18 Keysight P9241 42 43A Oscilloscopes Startup Guide 4 Install the Software The Keysight P600XA Chassis soft front panel will open The chassis FPGA firmware update options are in the About tab...

Страница 19: ...he P9241 42 43A oscilloscope _ WaveGen Identify LED blue WaveGen output enabled blinking blue identify oscilloscope Power LED Chassis ground terminal Probe Comp terminal Waveform generator output Exte...

Страница 20: ...source and the operator or bystanders could receive an electric shock LED Color When Run state LED Green Acquisitions are running Red Acquisitions are stopped Amber Waiting for a single acquisition to...

Страница 21: ...m generator sync pulse or calibration signal For more information see the Keysight P9241 42 43A Oscilloscopes Soft Front Panel SFP User s Guide Ref I O input output CAUTION Maximum voltage at oscillos...

Страница 22: ...anel connectors are used by the P9241 42 43A oscilloscope The other rear panel connectors are reserved for future use Power 15 VDC 6A Max 10MHz In 10MHz Out Trig A Trig B To Host PC USB 3 0 USB 2 0 ho...

Страница 23: ...Clean the external surfaces of the oscilloscope with a soft cloth dampened with a mixture of mild detergent and water 3 Make sure that the instrument is completely dry before reconnecting it to a pow...

Страница 24: ...24 Keysight P9241 42 43A Oscilloscopes Startup Guide 5 Connecting the Oscilloscope...

Страница 25: ...the oscilloscope in a bench top setting provide at least 4 100 mm clearance at the sides of the oscilloscope for proper cooling Do not orient multiple instruments in a way that would direct warm air...

Страница 26: ...few seconds Open the P924xA Oscilloscope Soft Front Panel SFP 1 From the Windows operating system Start menu choose Start All Programs Keysight InfiniiVision Oscilloscope Keysight InfiniiVision SFP 2...

Страница 27: ...w up in the Keysight InfiniiVision Launcher window Reboot your PC This may be needed after a software update or the first time a P924xA oscilloscope is plugged into a USB port it has not previously be...

Страница 28: ...s Startup Guide 6 Verify Operation Run the Oscilloscope s Hardware Self Test 1 Keysight InfiniiVision P924xA SFP interface click the top left blue menu icon and choose Utilities Service Menu 2 In the...

Страница 29: ...cope s functionality Hardware Self Test is designed to provide an 80 confidence level that the oscilloscope is operating properly If the Hardware Self Test fails See Return an Instrument for Service o...

Страница 30: ...30 Keysight P9241 42 43A Oscilloscopes Startup Guide 6 Verify Operation...

Страница 31: ...924xA Oscilloscope Soft Front Panel SFP on page 26 Connect Probes to the Oscilloscope 1 Connect the oscilloscope probe to an oscilloscope channel BNC connector 2 Connect the probe s retractable hook t...

Страница 32: ...The main differences between using the interface on a standalone oscilloscope and a modular oscilloscope are Instead of pressing front panel keys to open softkey menus you use the top left blue Main...

Страница 33: ...ge 1 Choose Main Menu Help Menu 2 In the Help Menu click the Language softkey label button 3 In the Language popup menu select the desired language The following languages are available Czech English...

Страница 34: ...lt Configuration Settings Horizontal Normal mode 100 s div scale 0 s delay center time reference Vertical Analog Channel 1 on 5 V div scale DC coupling 0 V position 1 M impedance Trigger Edge trigger...

Страница 35: ...annels where no signal is found are turned off The trigger source is selected by looking for the first valid waveform starting with external trigger then continuing with the lowest number analog chann...

Страница 36: ...n Measurements and Statistics 1 To turn on measurements choose Main Menu Measure Measurements 2 To turn on measurement statistics choose Main Menu Measure Statistics You should see a display similar t...

Страница 37: ...rement 7 Keysight P9241 42 43A Oscilloscopes Startup Guide 37 Learn the Oscilloscope Display The oscilloscope display contains acquired waveforms setup information measurement results and the softkey...

Страница 38: ...dentifiers and analog trigger and ground level indicators Each analog channel s information appears in a different color Signal detail is displayed using 256 levels of intensity To adjust waveform int...

Страница 39: ...the selected menu Softkey labels These labels describe softkey functions Typically softkeys let you set up additional parameters for the selected mode or menu At the top of the menu hierarchy clicking...

Страница 40: ...40 Keysight P9241 42 43A Oscilloscopes Startup Guide 7 Make a Measurement...

Страница 41: ...tic control of instrumentation while providing a greater degree of instrument interchangeability and code reuse IVI drivers currently come in two basic types IVI COM and IVI C Although the functionali...

Страница 42: ...o each LabVIEW instr lib directory for each version of LabVIEW you have on your computer for example C Program Files x86 National Instruments LabVIEW version instr lib Keysight product model If you in...

Страница 43: ...rol icon in the taskbar and choose Utilities Interactive IO from the popup menu see the SCPI Programmer s Guide for complete instructions On the host PC that is the PC that has the USB 3 0 connection...

Страница 44: ...ndow enter commands in the Command field and click Send Command Read Response or Send Read NOTE The oscilloscope appears under the LAN TCPIP0 interface when the P9241 42 43A oscilloscope s driver is c...

Страница 45: ...ng interface API together at the same time This can be useful for example because it lets you change oscilloscope settings while debugging remote programs However the SFP can become locked out while t...

Страница 46: ...d PC that has the IO Libraries Suite installed click the Keysight IO Control icon in the taskbar and choose Utilities Interactive IO from the popup menu 2 In the Keysight Interactive IO application ch...

Страница 47: ...s is TCPIP0 10 112 93 141 hislip37 0 0 INSTR or TCPIP0 lab pxi 3 cos is keysight com hislip37 0 0 INSTR If you are running the Interactive IO application on the controller PC you can use the 127 0 0 1...

Страница 48: ...48 Keysight P9241 42 43A Oscilloscopes Startup Guide 8 Applications Programming Interface API Overview...

Страница 49: ...on operating 4 500 m 14 764 ft Pollution Degree The P9241 42 43A oscilloscopes may be operated in environments of Pollution Degree 2 or Pollution Degree 1 Pollution Degree Definitions Pollution Degree...

Страница 50: ...characteristics To download the data sheet for the P9241 42 43A oscilloscopes please visit www keysight com products P9241A Measurement Category Oscilloscope Measurement Category on page 50 Measureme...

Страница 51: ...ion Caution refer to accompanying documentation This symbol indicates separate collection for electrical and electronic equipment mandated under EU law as of August 13 2005 All electric and electronic...

Страница 52: ...52 Keysight P9241 42 43A Oscilloscopes Startup Guide 9 Reference...

Страница 53: ...ency response analyzer 14 front panel features 19 G Gen Out 19 Gen Out output 21 German user interface and Quick Help 33 graphical user interface language 33 H hardware self test 28 help built in 32 h...

Страница 54: ...d Quick Help 33 S SCPI interface 42 SENT triggering and analysis 14 setup default 33 SFP and remote API concurrent 45 shipment contents 13 shipment contents P9241 42 43A 13 Simplified Chinese user int...

Отзывы: