Series Connections
Load, Sense, and Diode Connections
Additional Cautions When Using a Boost Supply in Series
Connecting power supplies in series provides a greater voltage capability than can be obtained from a
single unit. Note the following important considerations:
If your device under test does not have any energy sourcing ability such as a battery, power sup-
ply, or large energy storage device, the power supplies can be connected and operated in series.
Observe all applicable warnings and cautions (see below).
If your device under test includes a small capacitance, it is may be acceptable to connect power
supplies in series in most cases. Refer to the
table at the end of this section for
detailed information.
l
Always use series connections with a series protection diode when devices such as large capa-
citors, power supplies, batteries, or any other energy sources that may force current back into the
power supply are connected to the output. This diode protects the units from damage due to
reverse current as described under
. If using the series diode is not
acceptable in your application, please contact Keysight Technologies to speak to a power product
support engineer for assistance.
The following warnings and cautions must be followed in all cases:
SHOCK HAZARD Floating voltages must not exceed 240 VDC. No output terminal
may be more than 240 VDC from chassis ground.
To Prevent Possible Equipment Damage:
l
Only connect units of identical voltage
and
current ratings in series.
l
Do not connect N6900 models with N7900 models.
l
Lock the
closed on models that include them. Output relays are not
rated to switch voltages higher than the individual instrument rating.
l
Always turn the AC power on and off together. Never leave any units powered on
while the others are off.
Keysight N6900/N7900 Series Operating and Service Guide
79
2 Installing the Instrument
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...