![Keysight Technologies N5511A Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/keysight-technologies/n5511a/n5511a_user-manual_1962254060.webp)
60 N5511A Phase Noise Test System User’s Guide
Absolute Measurement Fundamentals
The Phase-Lock Loop Circuit
The Phase-Lock Loop Circuit
The Capture and Drift tracking ranges
Like other PLL circuits, the phase lock loop created for the measurement has a
Capture Range and a drift tracking range. The Capture Range is equal to 5% of
the system's peak tuning range, and the drift tracking range is equal to 24% of
the system's peak tuning range.
The system's peak tuning range is derived from the tuning characteristics of
the VCO source used for the measurement.
illustrates the
relationship that typically exists between the VCO's peak-to-peak tuning range
and the tuning range of the system. The system's drift tracking range is limited
to a small portion of the peak tuning range to minimize the possibility of
measurement accuracy degradation caused by non-linearity across the VCO's
tuning range.
Peak tune range (PTR)
The peak tuning range is determined using two parameters:
— VCO tuning sensitivity (Hz/Volt)
— Total voltage tuning range (Volts)
PTR = (VCO Tuning Sensitivity) X (Total Voltage Tuning Range)
PTR = (100 Hz/V) X (10 V) = 1000 Hz
Figure 5-5
Capture and Drift-Tracking Range with Tuning Range of VCO
As an example:
A Peak Tuning Range of 1000 Hz provides the following ranges:
Capture Range
= 0.05 X 1000 Hz = 50 Hz
Drift Tracking Range
= 0.24 X 1000 Hz = 240 Hz
Содержание N5511A
Страница 1: ...User s Guide Keysight N5511A Phase Noise Test System...
Страница 4: ...4...
Страница 11: ...Contents N5511A Phase Noise Test System User s Guide 11...
Страница 12: ...12 N5511A Phase Noise Test System User s Guide Contents...
Страница 38: ...38 N5511A Phase Noise Test System User s Guide Phase Noise Basics What is Phase Noise...
Страница 54: ...54 N5511A Phase Noise Test System User s Guide Expanding Your Measurement Experience GUI Features...
Страница 166: ...166 N5511A Phase Noise Test System User s Guide Absolute Measurement Examples OCXO Dual Channel Measurement...