16
Keysight M9035A PXIe Embedded Controller Startup Guide
Step 3: Install the M9035A Embedded Controller
Follow these steps to install the M9035A Embedded Controller in a PXIe chassis.
1
Ensure the PXIe chassis is turned off. The chassis should be plugged into an
AC power source; the AC power cord grounds the chassis and protects it from
electrical damage while modules are installed.
2
On the chassis, set the rear panel
INHIBIT
switch to
DEF
.
3
Remove the screw protection caps from the four M9035A retaining screws.
4
Push down on the controller’s ejector/injector handle.
5
Carefully align the M9035A board edges with the chassis guide rails for slot 1
(red guide rails) and insert the controller into the guide rails.
6
Push inward on the module until it is firmly seated in the chassis. (Do not force
the handle if there is resistance; this may damage the connectors and/or
backplane.)
7
Pull up on the ejector/injector handle to firmly seat the controller.
8
Tighten the module’s four (4) captive retaining screws.
To ensure mandatory safety requirements are being met, the
module must be installed in a chassis which has been certified and
marked by a Nationally Recognized Testing Lab (such as CSA, UL,
TUV, ETL etc.) in which all the means of protection are properly
implemented. NOTE: CE marking alone is not adequate.
Some non-Keysight PXIe chassis manufacturers install small
chassis stops just to the left of the slot 1 guide rails (both top and
bottom). Refer to the photo below. These must be removed prior to
installing the M9035A Embedded Controller. They snap in and are
easily pulled out.
Remove these
chassis stops