Obsolete and Discontinued Commands
:MEASure:TVOLt
Query Syntax
:MEASure:TVOLt? <value>, [<slope>]<occurrence>[,<source>]
<value> ::= the voltage level that the waveform must cross.
<slope> ::= direction of the waveform.
A rising slope is indicated by
a plus sign (+).
A falling edge is indicated by a minus
sign (-).
<occurrence> ::= the transition to be reported.
If the occurrence
number is one, the first crossing is reported.
If
the number is two, the second crossing is reported,
etc.
<source> ::= {<digital channels> | CHANnel<n> | FUNCtion | MATH}
<digital channels> ::= {DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
When the :MEASure:TVOLt? query is sent, the displayed signal is searched for the
specified voltage level and transition. The time interval between the trigger event
and this defined occurrence is returned as the response to the query.
The specified voltage can be negative or positive. To specify a negative voltage,
use a minus sign (-). The sign of the slope selects a rising (+) or falling (-) edge. If
no sign is specified for the slope, it is assumed to be the rising edge.
The magnitude of the occurrence defines the occurrence to be reported. For
example, +3 returns the time for the third time the waveform crosses the specified
voltage level in the positive direction. Once this voltage crossing is found, the
oscilloscope reports the time at that crossing in seconds, with the trigger point
(time zero) as the reference.
If the specified crossing cannot be found, the oscilloscope r9.9E+37. This
value is returned if the waveform does not cross the specified voltage, or if the
waveform does not cross the specified voltage for the specified number of times in
the direction specified.
If the optional source parameter is specified, the current source is modified.
Return Format
<value><NL>
<value> ::= time in seconds of the specified voltage crossing
in NR3 format
NOTE
The :MEASure:TVOLt command is obsolete and is provided for backward compatibility to
previous oscilloscopes. Use the :MEASure:TVALue command (see
Содержание InfiniiVision 3000T X Series
Страница 1: ...Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide...
Страница 40: ...40 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 50: ...50 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 64: ...64 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 164: ...164 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 254: ...254 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 286: ...286 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 10 CHANnel n Commands...
Страница 306: ...306 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 12 DEMO Commands...
Страница 314: ...314 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 13 DIGital d Commands...
Страница 344: ...344 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 16 EXTernal Trigger Commands...
Страница 352: ...352 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands FFT WINDow on page 362...
Страница 364: ...364 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands...
Страница 402: ...402 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 18 FUNCtion m Commands...
Страница 420: ...420 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 19 HARDcopy Commands...
Страница 442: ...442 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 21 MARKer Commands...
Страница 466: ...466 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands MEASure CLEar on page 464...
Страница 524: ...524 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands...
Страница 548: ...548 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 23 MEASure Power Commands...
Страница 656: ...656 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 26 POWer Commands...
Страница 666: ...666 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 27 RECall Commands...
Страница 888: ...888 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 29 SBUS n Commands...
Страница 978: ...978 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 30 SEARch Commands...
Страница 1006: ...1006 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 32 TIMebase Commands...
Страница 1232: ...1232 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 37 Obsolete and Discontinued Commands...
Страница 1240: ...1240 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 38 Error Messages...
Страница 1264: ...1264 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 39 Status Reporting...
Страница 1274: ...1274 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 40 Synchronizing Acquisitions...
Страница 1404: ...1404 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 42 Programming Examples...