Keysight Technologies E8257DS Series Скачать руководство пользователя страница 14

 10

User’s Guide E8251-90283

E8257DS02-S15

Safety and Regulatory Information

Electrostatic Discharge Protection

Protection against electrostatic discharge (ESD is essential while removing assemblies from or 

connecting cables to the instrument. Static electricity can build up on your body and can easily 

damage sensitive internal circuit elements when discharged. Static discharges too small to be 

felt can cause permanent damage. To prevent damage to the instrument:

always

 have a grounded, conductive table mat in front of your test equipment.

always

 wear a grounded wrist strap with grounding cord, connected to a grounded

conductive table mat, having a 1 M

 resistor in series with it, when handling components

and assemblies or when making connections.

always

 wear a heel strap (9300-1126) when working in an area with a conductive floor. If you

are uncertain about the conductivity of your floor, wear a heel strap.

always

 ground yourself before you clean, inspect, or make a connection to a static-sensitive

device or test port. You can, for example, grasp the grounded outer shell of the test port or

cable connector briefly.

always

 ground the center conductor of a test cable before making a connection to the

instrument test port or other static-sensitive device. This can be done as follows:
1. Connect a short to one end of the cable to short the center conductor to the outer

conductor.

2. While wearing a grounded wrist strap, grasp the outer shell of the cable connector.
3. Connect the other end of the cable to the test port and remove the short from the cable.

Figure 4 

ESD Protection Setup

Содержание E8257DS Series

Страница 1: ...references to Agilent Please note that Agilent s Test and Measurement business has become Keysight Technologies For more information go to www keysight com Millimeter Source Modules Keysight Technolog...

Страница 2: ...the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227...

Страница 3: ...Information 7 Introduction 7 Safety Earth Ground 7 Declaration of Conformity 7 Statement of Compliance 7 Before Applying Power 8 Servicing 9 Connector Care and Cleaning Precautions 9 Electrostatic Di...

Страница 4: ......

Страница 5: ...User s Guide E8251 90283 1 E8257DS02 S15...

Страница 6: ...Source Module Interface cable 2 meter RF cable SMA m to SMA m 1 meter Description The millimeter wave source modules are designed to work with the E8247C E8257C E8257D E8267C or E8267D PSG Series Synt...

Страница 7: ...Refer to Figure 1 2 Connect the RF cable included with this option from the SMA RF Input connector on the millimeter wave source module to the RF Output connector on the PSG using the adapter listed...

Страница 8: ...typical 2 Not traceable to NIST above 110 GHz 8 dBm 6 dBm 5 dBm 5 dBm 13 dBm 15 dBm3 3 Up to 200 GHz rolling off at 25 dBm typical at 220 GHz as measured by OML s calorimeter 25 dBm4 4 Output power e...

Страница 9: ...epth dimension excludes the output waveguide length 3 Option EA2 Table 5 OML and Keysight Model Numbers OML Model Number Keysight Model Number S15MS AG E8257DS15 S12MS AG E8257DS12 S10MS AG E8257DS10...

Страница 10: ...lable on the E8257DS02 EA2 Electronically Controlled Attenuator Available on the E8257DS12 only inside modules chassis controlled by DC voltage increases module size 50 dB attenuator range use PSG LF...

Страница 11: ...rthing ground incorporated in the power cord The mains plug shall be only be inserted in a socket outlet provided with a protective earth contact Any interruption of the protective conductor inside or...

Страница 12: ...grounding by not using this cord may cause product damage and the risk of electrical shock This product is designed for use in Installation Category II and Pollution Degree 2 Before switching on this...

Страница 13: ...g device It disconnects the mains circuits from the mains supply before other parts of the instrument Alternatively an externally installed switch or circuit breaker which is readily identifiable and...

Страница 14: ...ing components and assemblies or when making connections always wear a heel strap 9300 1126 when working in an area with a conductive floor If you are uncertain about the conductivity of your floor we...

Страница 15: ...the product frame or chassis The CE mark is a registered trademark of the European Community The Keysight email address is required by EU directives applicable to our product The CSA mark is a regist...

Страница 16: ...vice complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB du Canada Acoustic Statement European Machinery Directive Acoustical noise emission LpA 70 dB Operator position Normal...

Страница 17: ...the Internet contact your field engineer In any correspondence or telephone conversation refer to the Keysight product by its model number and full serial number With this information the Keysight rep...

Страница 18: ...This information is subject to change without notice Keysight Technologies 2014 2019 Print Date January 2019 Supersedes August 2014 E8251 90283 www keysight com...

Отзывы: