Getting Started Guide                                                                                                                                          9

Safety & Environmental Information
Safety

Safety

This product has been designed and tested in accordance with accepted 

industry standards, and has been supplied in a safe condition.The 

documentation contains information and warnings that must be followed by 

the user to ensure safe operation and to maintain the product in a safe 

condition. 

Safety Compliance

This product complies with the essential requirements of the European Low 

Voltage Directive as well as current editions of the following standards (dates 

and editions are cited in the Declaration of Conformity): 

— IEC/EN 61010-1
— Canada: CSA C22.2 No. 61010-1
— USA: UL std no. 61010-1

Acoustic statement (European Machinery Directive) 

Acoustic noise emission 

 

LpA <70 dB 

 

Operator position

 

Normal operation mode per ISO 7779 

General Safety Notices 

If this product is not used as specified, the protection provided by the 

equipment could be impaired. This product must be used in a normal condition 

(in which all means for protection are intact) only.

No operator serviceable parts inside. Refer servicing to qualified personnel. To 

prevent electrical shock, do not remove covers.

This is a Safety Protection Class I Product (provided with a protective earthing 

ground incorporated in the power cord). The mains plug shall only be inserted in 

a socket outlet provided with a protective earth contact. Any interruption of the 

protective conductor inside or outside of the product is likely to make the 

product dangerous. Intentional interruption is prohibited.

Содержание E7760A

Страница 1: ...Getting Started Guide Keysight Wireless Test Set M1650A mmWave Transceiver for E7760A Wideband Transceiver ...

Страница 2: ...Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not re...

Страница 3: ... To receive the latest updates by email subscribe to Keysight Email Updates at the following URL http www keysight com find MyKeysight Information on preventing instrument damage can be found at www keysight com find PreventingInstrumentRepair Is your product software up to date Periodically Keysight releases software updates to fix known defects and incorporate product enhancements To search for ...

Страница 4: ...4 ...

Страница 5: ...an Class A EMC declaration 11 Declaration of Conformity 11 Ventilation 12 Power requirements 12 Using Accessories 12 Weight and Dimensions 13 Protecting against electrostatic discharge 13 Quick Start 15 Initial Inspection 16 Shipping Problems 17 Location and Mounting 17 Exterior Rear Panel Functions 19 Exterior Features 20 Front and Rear Panel Symbols 22 Troubleshooting 23 Where to get technical h...

Страница 6: ...6 Getting Started Guide Contents ...

Страница 7: ... found in this section Warning Statements and Symbols on page 8 Safety on page 9 Environmental Conditions Operating on page 10 EMC Electromagnetic Compatibility on page 11 Ventilation on page 12 Power requirements on page 12 Using Accessories on page 12 Weight and Dimensions on page 13 Protecting against electrostatic discharge on page 13 ...

Страница 8: ...cedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal...

Страница 9: ... Acoustic statement European Machinery Directive Acoustic noise emission LpA 70 dB Operator position Normal operation mode per ISO 7779 General Safety Notices If this product is not used as specified the protection provided by the equipment could be impaired This product must be used in a normal condition in which all means for protection are intact only No operator serviceable parts inside Refer ...

Страница 10: ...idity at 40 C Environmental Stress Testing Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of Storage Transportation and End use those stresses include but are not limited to temperature humidity shock vibration altitude and power line conditions Test Methods are aligned with IEC 60...

Страница 11: ...ation of Conformity IEC EN 61326 1 CISPR Pub 11 Group 1 class A AS NZS CISPR 11 ICES NMB 001 This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada South Korean Class A EMC declaration This equipment is Class A suitable for professional use and is for use in electromagnetic environments outside of the home Declaration of Conformity The Declaratio...

Страница 12: ...ing intake air for another instrument Another area of concern is verification that the maximum ambient operating temperature of the instrument s is not exceeded by cabinet installation Keysight recommends forced air convection whenever an instrument s are installed in a cabinet and further recommends that the maximum operating temperature of the cabinet be reduced 10 C from the lowest of the maxim...

Страница 13: ...lated wrist strap before touching the center pin of any connector and before removing any assembly from the test set Be sure that all instruments are properly earth grounded to prevent build up of static charge Perform work on all components or assemblies at a static safe workstation Keep static generating materials at least one meter away from all components Store or transport components in stati...

Страница 14: ...14 Getting Started Guide Safety Environmental Information Protecting against electrostatic discharge ...

Страница 15: ...5 Keysight Wireless Test Set M1650A mmWave Transceiver Getting Started Guide 2 Quick Start The following topics can be found in this section Initial Inspection on page 16 Location and Mounting on page 17 ...

Страница 16: ...ontents of the container against the table below Item Deliverable Description Getting Started Guide this document Provides first time power on instructions licensing information operating system information and general hardware information Keysight M1650A mmWave Transceiver RF Cable Assembly E7760 60006 In addition to test signals carries DC supply voltage from E7760A The M1650A is used in conjunc...

Страница 17: ...al or comparable shipping materials See Returning Your Test Set for Service on page 25 Location and Mounting It is recommended to suspend the transceiver above the Device Under Test DUT with the mmWave port pointed downwards at the DUT so that heat given off by the external cooling fins of the transceiver will rise away from the DUT Leave a minimum clearance of 2 5 inches 7 cm around the transceiv...

Страница 18: ...18 Getting Started Guide Quick Start Location and Mounting ...

Страница 19: ...ireless Test Set M1650A mmWave Transceiver Getting Started Guide 3 Exterior Rear Panel Functions The following topics can be found in this section Exterior Features on page 20 Front and Rear Panel Symbols on page 22 ...

Страница 20: ...Getting Started Guide Exterior Rear Panel Functions Exterior Features Exterior Features Figure 3 1 M1650A Front and Rear Views Figure 3 2 M1650A side view The features are described in the following table ...

Страница 21: ...lied RF Cable Assembly In addition to test signals the E7760A supplies DC power and control signals to this port Do not connect or disconnect the RF cable at this port or at the E7760A mmWave port while the E7760A is powered on 3 LED Status Indicator This LED will be lit and blue when the M1650A is being used as an output port providing a stimulus to the DUT or green if it is being used as an inpu...

Страница 22: ...ZZZZZZZZZZZZZ ICES NMB 001 Cet appareil ISM est conforme a la norme NMB du Canada This is a marking to indicate product compliance with the Industry Canadian Interference Causing Equipment Standard ICES 001 This is also a symbol of an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 The CSA mark is a registered trademark of the CSA International This symbol indicates sep...

Страница 23: ... Wireless Test Set M1650A mmWave Transceiver Getting Started Guide 4 Troubleshooting The following topics can be found in this section Identifying Problems on page 24 Returning Your Test Set for Service on page 25 ...

Страница 24: ...mWave signals are not being exchanged with the Device Under Test check the following 1 Is the RF Cable Assembly connected between the M1650A and the appropriate mm Wave Port of the E7760A 2 Is the E7760A powered on 3 Is the E7760A properly configured for example are the input and output ports selected appropriately for your test setup If no obvious problem in the test setup can be found contact Ke...

Страница 25: ...ices around the world to provide you with complete support for your wireless test set To obtain servicing information or to order replacement parts contact the nearest Keysight Technologies office listed under Locations for Keysight Technologies on page 26 In any correspondence or telephone conversations refer to your test set by its product number and full serial number ...

Страница 26: ... Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other Asia Pacific countries 65 6375 8100 Europe Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 ...

Страница 27: ...This information is subject to change without notice Keysight Technologies 2014 2016 Edition 1 October 2016 M1650 90001 www keysight com ...

Отзывы: