3
Measurement Clock Tests
32
DDR2(+LP) Compliance Testing Methods of Implementation
Probing for Measurement Clock Tests
When performing the Measurement Clock tests, the DDR2(+LP) Compliance Test Application will
prompt you to make the proper connections. The connections for Rising Edge and Pulse
Measurement Clock tests may look similar to the following diagram. Refer to the Connection tab in
DDR2 Electrical Performance Compliance application for the exact number of probe connections.
You can use any of the oscilloscope channels as the Pin Under Test (PUT) source channel. You can
identify the channels used for each signal in the Configuration tab of the DDR2(+LP) Compliance
Test Application. (The channel shown in
For more information on the probe amplifiers and differential probe heads, see
Probing,” starting on page 351.
Test Procedure
1 Start the automated test application as described in
“Preparing to Take Measurements"
2 Ensure that the RAM reliability test software is running on the computer system where the DDR2
Device Under Test (DUT) is attached. This software will perform a test on all the unused RAM on
the system by producing a repetitive burst of read-write data signals to the DDR2 memory.
3 Connect the differential solder-in probe head to the PUT on the DDR2 devices.
4 Connect the oscilloscope probes to any of the oscilloscope channels.
5 In the DDR2 Test application, click the Set Up tab.
6 Select the Speed Grade options. For the DDR2 Measurement Clock tests, you can select either
DDR2-667, DDR2-800 and DDR2-1066 speed grade. If other Speed Grade is selected, the
Measurement Clock test options will not be displayed at the Select tab.
7 Type in or select the Device Identifier as well as User Description from the drop-down list. Enter
your comments in the Comments text box.
Figure 6
Probing for Measurement Clock Tests
Infiniium Oscilloscope
InfiniiMax solder-in probe
DDR2 DIMM
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...