4- 72
Keysight B1507A User’s Guide, Edition 1
GUI Reference
Power Loss Calculation Software
•
Vgs(pl): Gate Plateau Voltage
You can change the minimum and maximum values on the X and Y-axes by clicking
the value.
Results
Figure 4-20
Results
This area shows the power loss data in the list and the trend chart formats, that was
calculated along your parameter settings specified in the Inputs.
a. List
Shows the loss data for the swept parameter values as the calculation result in the
list format.
•
Index
Shows the index number of the sweep step.
•
Sweep parameter
Shows the sweep parameter value specified in the Inputs.
•
Conduction Loss
Shows the conduction loss as the calculation result.
This is calculated from the following expression.
•
Switching Loss
Shows the switching loss as the calculation result.
This is calculated from either of the following expressions.
a
b
Rds on
Irms
2
Содержание B1507A
Страница 1: ...Keysight Technologies B1507A Power Device Capacitance Analyzer User s Guide...
Страница 27: ...1 Introduction...
Страница 59: ...2 Installation...
Страница 79: ...3 How To Perform Measurement...
Страница 109: ...4 GUI Reference...
Страница 189: ......