SENSe Subsytem
SENSe:AVERage 1|2|4|8|16
SENSe:AVERage?
Sets the averaging count for measurements.
Parameter
Typical Return
1, 2, 4, 8, or 16
+1
Set the moving average period to 4 counts: SENS:AVER 4
This parameter does not apply to the peak current measurement.
The
command sets this parameter to ON.
SENSe:CURRent[:PEAK]:HOLD:CLEar
Clears the peak held current measurement.
Parameter
Typical Return
(none)
(none)
Clear the peak current measurement: SENS:CURR:HOLD:CLE
Use
FETCh:CURRent:AMPLitude:MAXimum:HOLD?
to query the peak held current measurement.
3 SCPI Programming Reference
144
Keysight AC6800B Series Operating and Service Guide
Содержание AC6801B
Страница 1: ...Operating and Service Guide Keysight AC6800B Series Basic AC Sources...
Страница 16: ...AC6802B 1 Getting Started 16 Keysight AC6800B Series Operating and Service Guide...
Страница 17: ...AC6803B Keysight AC6800B Series Operating and Service Guide 17 1 Getting Started...
Страница 18: ...AC6804B 1 Getting Started 18 Keysight AC6800B Series Operating and Service Guide...
Страница 62: ......
Страница 196: ...4 Calibration Verification and Service 196 Keysight AC6800B Series Operating and Service Guide...