Safety Considerations

The following general safety precautions must be observed during all 

phases of operation, service, and repair of this instrument. Failure to 

comply with these precautions or with specific warnings elsewhere in this 

manual violates safety standards of design, manufacture, and intended 

use of the instrument. Keysight Technologies assumes no liability for the 

customer’s failure to comply with these requirements.

Before operation, review the instrument and manual, including the red 

safety page, for safety markings and instructions. You must follow these to 

ensure safe operation and to maintain the instrument in safe condition.

Safety Symbols

The apparatus will be marked with this 

symbol when it is necessary for the user 

to refer to the instruction manual in 

order to protect the apparatus against 

damage.

Hazardous laser radiation. 

Invisible laser radiation.

WARNING

The WARNING sign denotes a hazard. It calls attention to a procedure, 

practice or the like, which, if not correctly performed or adhered to, could 

result in injury or loss of life. Do not proceed beyond a WARNING sign 

until the indicated conditions are fully understood and met.

Содержание 81960A

Страница 1: ...Getting Started Guide Keysight 81960A Compact Tunable Laser Source Module...

Страница 2: ...ernment requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of commercial computer software...

Страница 3: ...Fitting Blind Panels for Front Loadable Module Slots 8 Fitting a Filler Module for Back Loadable Module Slots 9 Initial Safety Information for Tunable Laser Modules 10 Laser Safety Labels 11 Laser cl...

Страница 4: ......

Страница 5: ...de 1 Getting Started This chapter provides a general description of Keysight 81960A Tunable Laser Source Family Safety Considerations 6 Initial Safety Information for Tunable Laser Modules 10 Laser Sa...

Страница 6: ...eration review the instrument and manual including the red safety page for safety markings and instructions You must follow these to ensure safe operation and to maintain the instrument in safe condit...

Страница 7: ...Multichannel Systems Operating Environment The safety information in your mainframe s User s Guide summarizes the operating ranges for the Keysight 81960A Compact Tunable Laser Source modules In order...

Страница 8: ...r flow Fitting Blind Panels for Front Loadable Module Slots To fit the a blind panel part number 08163 40199 perform the following procedure 1 Position the blind panel as shown in Figure 1 on page 8 P...

Страница 9: ...dule for Back Loadable Module Slots The Keysight 81960A Filler Module must be used if you have not installed a back loadable Tunable Laser module into the 8164A B Lightwave Measurement System The Keys...

Страница 10: ...ble 1 Standard Laser Source Modules Laser Safety Information Keysight 81960A Laser type ECL Laser InGaAsP Wavelength Range 1505 nm 1630 nm Max CW output power 50 mW Beam waist diameter 9 m Numerical a...

Страница 11: ...e instrument WARNING Please pay attention to the following laser safety warning The laser output can be controlled by GUI GPIB state command and the front panel button Do not switch on the instrument...

Страница 12: ...12 Keysight 81960A Compact TLS Module Getting Started Guide 1 Getting Started NOTE The remote interlock function interrupts the laser current when the connector is open...

Страница 13: ...n continuous wave or modulated power With the 81960A Keysight sets a new mark in tunable laser performance with faster sweep speeds and repetition rates combined with the dynamic accuracy specificatio...

Страница 14: ...off using the button on its front panel using the State parameter in the instrument s Graphical User Interface or remotely using GPIB commands When the Active LED is lit the output is enabled When th...

Страница 15: ...ter adjustment and calibration The high performance in continuous sweeps also matches this laser well to the single sweep PDL and IL N7700A measurement engine The dynamic wavelength accuracy will sati...

Страница 16: ...ure constant measurement conditions The fiber is of Panda type with TE mode in the slow axis in line with the connector key Figure 4 PMF Output Connector For further details on connector interfaces an...

Страница 17: ...ht The angled contact connector symbol is colored green You should connect straight contact fiber end connectors with neutral sleeves to straight contact connectors and connect angled contact fiber en...

Страница 18: ...This information is subject to change without notice Keysight Technologies 2017 Edition 4 0 July 2017 Printed in Malaysia www keysight com...

Отзывы: