background image

Specications

This

section

lists

the

complete

16454A

specications

.

These

specications

are

the

performance

standards

and

limits

against

which

the

16454A

is

tested.

When

shipped

from

the

factory

,

the

16454A

meets

the

following

listed

specications

.

Supplemental

characteristics

are

intended

to

provide

information

that

is

useful

in

applying

the

instrument

by

giving

non-warranted

performance

parameters

.

These

are

denoted

as

typical,

typically

,

nominal

or

approximate.

Applicable

MUT

(Material

Under

T

est)

Size

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

See

T

able

1-1

Maximum

DC

Bias

Current

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

6

500

mA

Frequency

Range

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

1

kHz

to

1.0

GHz

typically

Operating

T

emperature

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

055

C

to

+200

C

Operating

Humidity

(@

wet

bulb

temperature

<40

C)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

Up

to

95%

RH

Non-operating

T

emperature

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

055

C

to

+200

C

Non-operating

Humidity

(@

wet

bulb

temperature

<65

C)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

Up

to

90%

RH

W

eight

(Large

T

est

Fixture)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

140

g

typically

(Small

T

est

Fixture)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

120

g

typically

Dimension

(Large

T

est

Fixture)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

30

mm

2

35

mm

H

typically

(Small

T

est

Fixture)

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

24

mm

2

30

mm

H

typically

T

able

1-1.

Applicable

MUT

Size

Fixture

Small

Large

Holder

A

B

C

D

b

3.1

mm

3.1

mm

6

mm

5

mm

c

8

mm

6

mm

20

mm

20

mm

h

3

mm

3

mm

8.5

mm

8.5

mm

Applicable

Instruments

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

4291B

RF

Impedance/Material

Analyzer

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

4294A

Precision

Impedance

Analyzer

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

:

E4991A

RF

Impedance/Material

Analyzer

Model

Necessary

options

4291B

Option

002

Option

012/014

1

4294A

I-B

ASIC

sample

program

disk

2

E4991A

Option

002

1

Used

for

temperature

characteristics

measurement.

2

Furnished

with

4294A

manual

set

1-2

General

Information

Содержание 16454A

Страница 1: ...Operation and Service Manual Keysight 16454A Magnetic Material Test Fixture ...

Страница 2: ......

Страница 3: ...8710 2081 1 2 Fixture Holder 16454 00601 1 3 Screw Hex Recess 0515 1050 2 4 Test fixture Large not assigned 1 5 Test fixture Small not assigned 1 6 Holder A 16454 25002 1 7 Holder B 16454 25001 1 8 Holder C WITHOUT HOLE 16454 25004 1 9 Holder D WITH HOLE 16454 25003 1 10 Holder Case 1540 0622 1 11 Hex Key 2 5 mm Across Flats 5188 4452 1 Carrying Case1 16454 60101 1 Operation and Service Manual1 16...

Страница 4: ... 1 Fixture Cap Large 7 16454 23002 1 Fixture Flange Small 8 16454 230011 1 Fixture Cap Small 9 16454 25002 1 Holder A 10 16454 25001 1 Holder B 11 16454 25004 1 Holder C WITHOUT HOLE 12 16454 25003 1 Holder D WITH HOLE 13 1540 0622 1 Holder Case 14 5188 4452 1 Hex Key 2 5 mm Across Flats 15 8710 2081 1 Tweezers 16 0470 0013 1 Thread Sealant 16454 60101 1 Carrying Case2 16454 90020 1 Operation and ...

Страница 5: ...Agilent 16454A Magnetic Material Test Fixture Operation and Service Manual Agilent Part No 16454 90020 Printed in JAP AN July 2001 Fifth Edition ...

Страница 6: ...copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of the Agilent Technologies Agilent Technologies Japan Ltd Component Test PGU Kobe 1 3 2 Murotani Nishi ku Kobe shi Hyogo 651 2241 Japan c Copyright 1993 1999 2000 2001 Agilent Technologies Japan Ltd ...

Страница 7: ...corporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated December 1993 First Edition part number 16454 90000 February 1999 Second Edition part number 16454 90000 January 2000 Third Edition part number 16454 90000 April 2001 Fourth Edition part number 16454 90010 July 2001 Fifth Edition part number 16454 90020 iii ...

Страница 8: ...ages may exist even with the power cable removed To avoid injuries always disconnect power and discharge circuits before touching them DO NOT Service Or Adjust Alone Do not attempt internal service or adjustment unless another person capable of rendering rst aid and resuscitation is present DO NOT Substitute Parts Or Modify Instrument Because of the danger of introducing additional hazards do not ...

Страница 9: ...tution s calibration facility or to the calibration facilities of other International Standards Organization members Warranty This Agilent Technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date of shipment except that in the case of certain components listed in Instrument Speci cations of this manual the warranty shall be for...

Страница 10: ...s the implied warranties of merchantability and tness for a particular purpose Exclusive Remedies The remedies provided herein are buyer s sole and exclusive remedies Agilent Technologies shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assist...

Страница 11: ...of fault A terminal marked with this symbol must be connected to ground in the manner described in the installation Operation manual and before operating the equipment Frame or chassis terminal A connection to the frame chassis of the equipment which normally includes all exposed metal structures Alternating current power line Direct current power line Alternating or direct current power line W ar...

Страница 12: ...APC 7 R is a U S registered trademark of the Bunker Ramo Corporation viii ...

Страница 13: ...ment 2 3 3 Theory on Material Measurement Magnetic Material Measurement 3 1 Permeability De nition 3 1 Measurement Principle of Magnetic Material 3 1 Structure of 16454A Test Fixture 3 4 4 Operation Connecting the Test Fixture 4 1 Selecting Fixture and Holder 4 1 Connecting the Test Fixture to the Test Head 4 2 Performing SHORT Compensation 4 3 Placing the MUT into the Test Fixture 4 3 5 Service I...

Страница 14: ...bility Measurement Accuracy r v s Frequency F 3 1 7 1 9 Typical Permeability Measurement Accuracy r v s Frequency F 10 1 8 3 1 Vector Diagram of Complex Relative Permeability and Loss Tangent 3 1 3 2 Relationship among Current Magnetic Flux and Magnetic Flux Density 3 2 3 3 Measurement Principle When Using 16454A Test Fixture 3 2 3 4 Loss of Magnetic Material 3 3 3 5 16545A Residual Impedance 3 4 ...

Страница 15: ... chapter Initial inspection of the 16454A see Chapter 2 Ordering replaceable parts for the 16454A see Chapter 5 For measurement procedures using the 16454A see the 4291B RF Impedance Material Analyzer User s Guide Product Description The 16454A is used to measure the permeability of a toroidal core General Information 1 1 ...

Страница 16: ...Operating Humidity wet bulb temperature 40 C Up to 95 RH Non operating Temperature 055 C to 200 C Non operating Humidity wet bulb temperature 65 C Up to 90 RH W eight Large Test Fixture 140 g typically Small Test Fixture 120 g typically Dimension Large Test Fixture 30 mm 2 35 mm H typically Small Test Fixture 24 mm 2 30 mm H typically Table 1 1 Applicable MUT Size Fixture Small Large Holder A B C ...

Страница 17: ... F 0 rmf 0 004f Typical Eb 1 0 rm 0 rm tan 100 Typical Where f is measurement frequency GHz F h ln c b mm h is the height of MUT mm b is the inner diameter of MUT c is the outer diameter of MUT tan is the measured value of loss tangent rm 0 is the measured value of permeability Conditions of accuracy characteristics Use the Low Z Test Head for permeability measurement OPEN SHORT 50 calibration mus...

Страница 18: ...Figure 1 1 Typical Permeability Measurement Accuracy F 0 5 Figure 1 2 Typical Permeability Measurement Accuracy F 3 3 F hln c b 1 4 General Information ...

Страница 19: ...Figure 1 3 Typical Permeability Measurement Accuracy F 10 Figure 1 4 Typical Permeability Loss Tangent tan Measurement Accuracy F 0 5 3 F hln c b General Information 1 5 ...

Страница 20: ...Figure 1 5 Typical Permeability Loss Tangent tan Measurement Accuracy F 3 Figure 1 6 Typical Permeability loss Tangent tan Measurement Accuracy F 10 3 F hln c b 1 6 General Information ...

Страница 21: ...Figure 1 7 Typical Permeability Measurement Accuracy r v s Frequency F 0 5 Figure 1 8 Typical Permeability Measurement Accuracy r v s Frequency F 3 3 F hln c b General Information 1 7 ...

Страница 22: ...Figure 1 9 Typical Permeability Measurement Accuracy r v s Frequency F 10 3 F hln c b 1 8 General Information ...

Страница 23: ... by carefully performing an incoming inspection to check the magnetic material test xture set for signs of physical damage and missing contents If any discrepancy is found notify the carrier and Agilent Technologies Your Agilent Technologies sales o ce will arrange for repair and replacement without waiting for the claim to be settled Inspect the shipping container for damage Keep the shipping mat...

Страница 24: ... Test xture Large not assigned 1 5 Test xture Small not assigned 1 6 Holder A 16454 25002 1 7 Holder B 16454 25001 1 8 Holder C 16454 25003 1 9 Holder D 16454 25004 1 10 Holder Case 1540 0622 1 11 Hex Key 2 5mm Across Flats 8710 1181 1 0 Carrying Case1 16454 60101 1 0 Operation and Service Manual1 16454 90010 1 1 These parts are not shown in this gure 2 2 Initial Inspection ...

Страница 25: ...terials If this material is not available comparable packaging materials may be used Wrap the magnetic material test xture in heavy paper and pack in anti static plastic packing material Use su cient shock absorbing material on all sides of the 16454A to provide a thick rm cushion and to prevent movement Seal the shipping container securely and mark it FRAGILE Initial Inspection 2 3 ...

Страница 26: ......

Страница 27: ...meability 3 r 0 r 0 j 00 r As shown in Figure 3 1 complex relative permeability can be expressed in a vector diagram The loss factor of a magnetic material is expressed as loss tangent tan which is the ratio of the imaginary component r to the real component r of the complex relative permeability Figure 3 1 V ector Diagram of Complex Relative Permeability and Loss Tangent Measurement Principle of ...

Страница 28: ...e 3 2 is expressed as Equation 3 3 Note that L indicates the self inductance of the closed loop Equation 3 3 Magnetic Flux Induced by Current in Closed Loop 8 LI Furthermore this magnetic ux 8 also can be expressed by integrating the magnetic ux density B throughout the enclosed surface as shown in Figure 3 2 See Equation 3 4 Equation 3 4 Relationship between Magnetic Flux and Magnetic Flux Densit...

Страница 29: ...tion 3 7 can be obtained Equation 3 7 Self Inductance of Measurement Circuit L 0 2 f r 01 hln c b h0ln e a g By transforming Equation 3 7 to calculate the relative permeability r of the DUT Equation 3 8 can be obtained Equation 3 8 Relative Permeability of DUT r 2 L 0 Lss 0hlnc b 1 Lss in Equation 3 9 indicates the self inductance when a DUT is not mounted in the test xture Equation 3 9 Self Induc...

Страница 30: ...UT mounted the residual impedance Z res can be calculated from the measured impedance Z sm with no DUT mounted in 16454A in SHORT state Equation 3 14 16454A Residual Impedance Z3 res Z3 sm 0Z3 ss Errors due to residual impedance can be minimized by SHORT compensation The impedance after error compensation Z comp can be calculated from the measured impedance Z m with a DUT mounted in 16454A as show...

Страница 31: ...UT size for each xture is listed in Table 5 1 Table 4 1 MUT Size For Test Fixtures Fixture Small Large Holder A B C D MUT Outer Diameter mm 8 mm 6 mm 20 mm 20 mm MUT Inner Diameter mm 3 1 mm 3 1 mm 6 mm 5 mm MUT Height mm 3 mm 3 mm 8 5 mm 8 5 mm Figure 4 1 shows the dimensions of the MUT holder Figure 4 1 Dimensions of the MUT Holder Operation 4 1 ...

Страница 32: ...y that the connector sleeve is retracted fully as shown in Figure 4 3 Figure 4 2 Figure 4 3 3 Secure the test xture to the xture holder using the two screws 4 Connect the connector on the underside of the test xture to the APC 7 connector on the test head 5 Secure the xture holder to the test station using the two screws Figure 4 4 Connecting the Test Fixtures 16454A Small 4 2 Operation ...

Страница 33: ...ts for the residual impedance due to the test xture 1 Remove the cap of the xture 2 Place a MUT holder only in the xture 3 Replace the cap by screwing tightly Placing the MUT into the Test Fixture How to place the MUT on the 16454A is shown below Operation 4 3 ...

Страница 34: ...1 Remove the cap of the xture 2 Place a MUT onto the MUT holder and insert it into the xture 3 Replace the cap by screwing tightly 4 4 Operation ...

Страница 35: ...54A Magnetic Material Test Fixture Replaceable Parts Table 5 1 lists the replaceable parts The parts listed in this table can be ordered from your nearest Agilent Technologies o ce Ordering information should include the Agilent part number and the quantity required Service 5 1 ...

Страница 36: ... Cap Large 7 16454 23002 1 Fixture Flange Small 8 16454 230011 1 Fixture Cap Small 9 16454 25002 1 Holder A 10 16454 25001 1 Holder B 11 16454 25003 1 Holder C 12 16454 25004 1 Holder D 13 1540 0622 1 Case 14 8710 1181 1 Hex Key 2 5mm Across Flats 15 8710 2081 1 Tweezers 16 0470 0013 1 Thread Sealant 0 16454 60101 1 Carrying Case2 0 16454 90000 1 Speci cation and Service Manual2 1 Agilent internal...

Страница 37: ...m calibration at the APC 7 R terminal of the measurement instrument 2 Place the xture small on the calibrated APC 7R terminal of the measurement instrument 3 Read LS and RS values for each test xture The guideline is as follows Table 5 2 Fixture Impedance Check Guideline Fixture Frequency Parameter Guideline Small 100 MHz LS 1 nH 6 0 5 nH RS 100 m Large 100 MHz LS 5 5 nH 6 2 5 nH RS 300 m Service ...

Страница 38: ......

Страница 39: ... 1 800 452 4844 fax 1 888 900 8921 Canada Test and Measurement Call Center tel 1 877 894 4414 fax 1 888 900 8921 China tel 800 810 0189 fax 800 820 2816 Europe tel 31 20 547 2323 fax 31 20 547 2390 Japan Call Center tel 0120 421 345 tel 81 426 56 7832 fax 81 426 56 7840 Korea tel 82 2 2004 5004 fax 82 2 2004 5115 Latin America tel 305 269 7500 fax 305 269 7599 Taiwan tel 0800 047 866 fax 0800 286 ...

Страница 40: ......

Страница 41: ...This information is subject to change without notice Keysight Technologies 1993 2015 February 2015 16454 90020 16454 90020 www keysight com ...

Отзывы: