
5
3.1. Main window, adjustment mode and devices mode.
Following turning on of the controller the main window is displayed. On the top of the
display (1) boiler water temperature is shown, and on the bottom operation mode is
displayed. Symbol „*” displayed in the right bottom corner indicates burner flame
detection. Lights below the display indicate particular outputs and when switched on
they indicate their operation.
B O I L E R
T E M P .
6 7 c
S T O P
*
Basic operation of the controller is carried out by setting the desired temperature of
the boiler. To do this turn the boiler thermostat knob (12) according to the desired
setting and confirm with OK button (Press the knob).
D E S I R E D B O I L E R
T E M P E R A T U R E → 5 8 c
CAUTION!
When the household thermostat input works in the mode of adaptation,
any attempts to change the boiler programmed temperature may end with failure, i.e.
when the new value is confirmed, the change in the boiler programmed temperature
to the value resulting from the algorithm of adaptation is automatic.
CAUTION!
If the heating system is fitted with the domestic water tank, boiler water
temperature controlled and maintained by the controller during tank preheating may
be higher than desired temperature setting programmed with thermostat knob.
Содержание RK-2006LP
Страница 1: ...OPERATING MANUAL RK 2006LP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER Version DC19...
Страница 2: ......
Страница 32: ...32 Figure 2 RK 2006LP Controller connection diagram...
Страница 36: ...36...
Страница 37: ...37...
Страница 38: ...38...