Key West Boats 239FS Скачать руководство пользователя страница 8

Fresh Water System Troubleshooting

Fresh Water Pump Runs, but does not pump water

Water Tank is empty.  Fill the Tank

Intake hose from the tank to the pump is damaged causing the pump to suck air.  Check Hose

Strainer is clogged.  Clean Strainer

Fresh Water Pump Run, but flow is reduced

Intake hose from the tank to the pump is damaged causing the pump to suck air.  Check Hose

Water Tank vent line is kinked or blocked creating a vacuum in the tank.  Check Vent Line

Strainer is partially clogged.  Clean Strainer

Fresh Water Faucet is not fully open.  Open Valve fully

Partial block or kink in hoses between pump and faucet.  Check hoses

Low Voltage to Pump.  Check connections for loose or corroded wiring.  Check battery voltage

Damaged or defective pump.  Replace pump

The Fresh Water washdown pump continues to run, even after faucet is closed

Intake hose from the tank to the pump is damaged causing the pump to suck air.  Check Hose

Water Tank vent line is kinked creating a vacuum in the tank.  Check Vent Line

Strainer is clogged.  Clean Strainer

Pressure Regulator in pump is defective.  Replace pump or pump regulator

Fresh Water Tank runs out of water excessively fast

Leak in the tank or leak in intake hose going to the pump.  Check tank integrity by filling all the way and inspect for 

leaks.  If Leak is found, consult dealer regarding repair/replacement.  Check connections on intake hose to the 

pump for leaks.

A kink/block in the Water tank vent line can cause the tank to fill up prematurely, even though it isn’t full due to 

lack of air escaping.  Check tank vent line and ensure it is not blocked or kinked.

Содержание 239FS

Страница 1: ...Quick Guide and Schematics...

Страница 2: ...re operating your boat safely and within the rules at all times Like all Key West Boats the 239FS was designed to be low maintenance ergonomic and an efficient boat to maintain and operate Familiarizi...

Страница 3: ...or at a marina the pressurized system will prevent overfilling Any blockage of the vent vent line and or orifice line will prematurely trigger the shut off on the fuel nozzle and will prevent you fro...

Страница 4: ......

Страница 5: ...hat is located in the aft end of the port transom storage box The pump is controlled by a switch and circuit breaker See Electrical Schematics Water is supplied to the pump off of the accessory port o...

Страница 6: ...s not fully open Open Valve Fully Hose s are damaged and are either leaking and or sucking air Check hoses Low Voltage to Pump s Check connections for loose or corroded wiring Check battery voltage Pu...

Страница 7: ...he strainer screen by untwisting the clear cap and clean the screen The pump features a built in pressure regulator that will shut the pump off when pressure is achieved in the system The fresh water...

Страница 8: ...ck battery voltage Damaged or defective pump Replace pump The Fresh Water washdown pump continues to run even after faucet is closed Intake hose from the tank to the pump is damaged causing the pump t...

Страница 9: ......

Страница 10: ......

Страница 11: ...e discharges to forward port thru hull near transom See Note A Below Console Recess Drain Gravity drain drains directly to the bilge Livewell Leaning Post Overflow Drain Optional Gravity drain connect...

Страница 12: ......

Страница 13: ......

Страница 14: ...in your boats interior use a sufficient quantity of water to dilute the chemical s when spraying off so that they do not affect the foam ball when draining out The seal ring needs to be kept free of d...

Страница 15: ...Replace Pump The Pump is defective Replace Pump Bilge pump will not run when the manual switch on the helm is engaged Circuit breaker below the pump s switch is tripped Reset circuit breaker The batt...

Страница 16: ...t feasible be installed with a battery charger to prevent discharge by the bilge pump Trim Tabs and optional power steering are connected directly to the battery and feature overcurrent protection The...

Страница 17: ...tions and terminals be checked at least twice a year and sprayed with a corrosion inhibiting spray at least once a year to protect and maintain the integrity of electrical connections Dealer Installed...

Страница 18: ......

Страница 19: ...Grey White...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Отзывы: