8
9
RS-232:
Connect a stripped wire to DB9 adapter cable for bi-directional RS-232 control. Refer to
the “Extending IR or RS-232 Control” section for more information.
➔
Set the Control rotary RS-232 Pass-through mode to control remote equipment.
➔
Supports baud rate up to 115,200bps
Power:
Power connection required at either Tx or Rx unit.
➔
12V/1.66A (20W) power supply
➔
Not compatible with third-party Power Over HDBaseT devices
IR In/Out:
Connect to the IR In terminals from the included IR Sensor or a control system.
Connect the included IR Emitter or hard-wire to control peripheral components from the
IR Out port.
Refer to the “Extending IR & RS-232 Control” for more information.
➔
Tx Unit IR In corresponds with Rx unit IR Out. Tx Unit IR Out corresponds with
Rx unit IR In.
➔
Rx Unit IR In corresponds with Tx unit IR Out. Rx Unit IR Out corresponds with
Tx unit IR In.
➔
Set the Control Rotary to adjust the IR In mode for IR Sensor (default at Rx unit) or
hard-wired IR (default at Tx unit)
➔
Ground pin is shared if using both channels of IR
KD-X444S_Manual.indd 8-9
6/5/18 12:20 PM