521 East 3
rd
Street Mt. Vernon, NY 10553
• www.keydigital.com
Rev 0
– Aug, 2020
22
Unit Control Ports
Unit Control Phoenix Connector
•
6-pin terminal block for Trigger In, IR and RS-232
•
TCP/IP and RS-232 commands may be found in the TCP/IP & RS-232 Commands section
•
Pinout:
o
Pin 1 = Trigger In
o
Pin 2 = IR In
o
Pin 3 = IR/Trigger Ground
o
Pin 4 = RS-232 Tx Data
o
Pin 5 = RS-232 Ground
o
Pin 6 = RS-232 Tx Data
TCP/IP Control Port
•
Default static IP address is 192.168.1.239, port 23
•
Connect an ether cable from the KD-UPS52U to a network router or connect a straight through cable
directly from a PC
•
Unit configuration, control, and firmware updates are achieved with Key Digital Management software
•
A single TCP/IP connection made at KD-UPS52U, KD-X100MRx, or KD Transmitter enables IP
connection to the KD-UPS52U and the KD Transmitter.
Ensure that the KD-UPS52U and the KD
Transmitter each device has been assigned a unique IP address to avoid IP conflicts.
IR Sensor
•
Used to collect line-of-sight IR from remote control
•
Receives signals from a 90° angle at up to 30ft away.
•
Mount an IR emitter from Compass Control Pro or to control by another professional control system