![Key Digital KD-MSVA4X4Pro Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/key-digital/kd-msva4x4pro/kd-msva4x4pro_setup-manual_1960340014.webp)
Page 14
RS-232 Commands:
The KD-MSVA4X4Pro provides access to all functions when used with an RS-232 control system.
For a complete list of all available RS-232 commands please see the “Technical” section at www.
keydigital.com.
Connection protocol is as follows:
»
Baud rate: 57,600
»
Data Bits: 8
»
Parity: None
»
Stop Bits: 1
»
Flow Control: None
Pin 5 – Ground
Pin 3 – Receive
Pin 2 – Transmit
RS-232 cable pin out
The commands are not case sensitive. The command lines are shown with spaces for clarity. No
spaces are required when entering commands.
All standalone units have ‘00’ as their default address. When multiple units are used as in an
expansion configuration, each unit will have a unique address. In this case, all below commands
should start with the Prefix:
‘A zz’
, where
zz = [01-99]
and represents the units System Address.
This will ensure the commands are sent to the correct unit.
Values for Commands:
Address
zz = 00-99
(Default standalone 4x4 is 00)
Inputs
xx = 01-99
(or A = All)
Outputs
xx = 01-99
(or A = All)
Output Volume
yy = 00-96
(Default is 80)
Output Bass
yy = 00-24
(Default is 12)
Output Middle
yy = 00-24
(Default is 12)
Output Treble
yy = 00-24
(Default is 12)
Output Balance
yy = 00-40
(Default is 20)
Output Delay
yy = 00-99
(Default is 00, each increment = 5.5ms)
Output Mute Interval
yy = 00-09
(Default is 00)
H
Help
PHI
Help with Input Setup Commands
PHO
Help with Output Setup Commands
PHC
Help with Control Setup Commands
PHT
Help with Status Commands
PN
Power On
PF