Key Digital KD-MAX8x8 Скачать руководство пользователя страница 5

6

7

Quick Setup Guide

1. 

Begin with the KD-MAX8x8 and all Input/Output devices turned off and power cables removed 

2. 

Connect analog audio sources to the desired 6-pin phoenix terminals and/or digital audio 
sources to the desired PCM inputs 

3. 

Connect the analog audio output amplifiers/receivers via the analog 6-pin phoenix terminals 
and digital destinations via the PCM outputs 

4. 

Connect power to the KD-MAX8x8, followed by all other input and output devices and turn 
them on 

5. 

If balanced audio input type is required for any of the analog inputs, set the desired input via 
the IR remote control using command sequence R2, XX, Audio Mode, 3.  Note that XX is the 
desired input number (01 – 08).  

6. 

Operate KD-MAX8x8 switcher via the front panel buttons, IR remote, serial IR or RS-232 
control

7. 

See TCP/IP and RS-232 Commands or Settings and Adjustments via Remote sections for 
more adjustments options

Settings and Adjustments via Remote

Many initial installation steps may be configured using the factory remote control.  Other advanced 
settings may be configured using USB and software downloaded from www.keydigital.com  

1

2

3

4

5

6

7

8

9

0

All Mute

Volume

Mute

Audio Mode

Video Mode

Balance

LipSync

Bass

Middle

Treble

Restore

All Restore

R1

R2

R3

R4

Power Off

Power On

www.keydigital.com

Tone Controls

Input Associated Audio Type

 

»

IR Button Sequence = R2, XX, Video Mode, Y

 

»

XX = Input # [01-08]

 

»

Y = Audio Type [1 = Analog, 2 = PCM, 3 = Analog to Analog,  
PCM to PCM]

Analog Input Audio Type

 

»

IR Button Sequence = R2, XX, Audio Mode, Y

 

»

XX = Input # [01-08]

 

»

Y = Audio Type [1 = L+/R+, 2 = L-/R-, 3 = Balanced, 4 = N/C]

Matrix Switching Command (Associated Audio)

 

»

IR Button Sequence = Audio Mode, X, Y

 

»

X = Output # [1-8]

 

»

Y = Input # [1-8]

Output Mute/Un-mute

 

»

IR Button Sequence = R1, X, Mute/Restore

 

»

X = Output # [1-8]

Output Volume Up/Down

 

»

IR Button Sequence = R1, X, Volume, Up/Down

 

»

X = Output # [1-8]

Output Volume Level

 

»

IR Button Sequence = R1, X, Volume, YY

 

»

X = Output # [1-8]

 

»

YY = Volume Level [00-99]

Set Unit Static IP Address to xxx.xxx.xxx.xxx

 

»

IR Button Sequence = R3, Bass, XXX, Video Mode, XXX, Video Mode, XXX,  
Video Mode, XXX

Set Unit Default Gateway/Router IP Address to xxx.xxx.xxx.xxx

 

»

IR Button Sequence = R3, Treble, XXX, Video Mode, XXX, Video Mode, XXX,  
Video Mode, XXX

 

»

Default IP address is 192.168.1.239, with default port 23 and default gateway 192.168.1.1

 

»

Please see the IR Remote Command List section for additional commands

Apply New Network Configuration

 

»

IR Button Sequence = R3, All Restore 

IR Remote Command List

IR Control is possible using remote model KD-REMOTEHM88 (included). Use the numerical 
keypad for X, Y, and Z values below. 

Advanced unit setup should be completed in the KD Wizard software found on  
www.keydigital.com

Command

Sequence

Input Setup 

Parameters

XX = input # (01-08)

Input associated input type

R2, XX, Video Mode, Y 
Y = 1 (Analog) / 2 (PCM) / 3 (both)

Set analog input type

R2, XX, Audio Mode, Y 
Y = [1 = L+/R+, 2 = L-/R-, 3 = Balanced, 4 = N/C]

Audio Output Setup

Parameters

XX = 01 – 08 
YY = 01 – 99, Up, Down

Set Output X to Association Input Y

Audio Mode, X, Y 
X = Output #[1-8] 
Y = Input #[1-8]

Set digital output XX = Analog input YY

R1, XX, Video Mode, YY

Set digital output XX = PCM input YY

R1, XX, R2, YY

Set PCM output XX = PCM input YY

R1, XX, R3, YY

Set ALL output Mute/Unmute

All Mute/All Restore

Set output XX ON/OFF

R1, XX, R4, 1/0

KD-MAX8x8 Manual.indd   6-7

12/23/17   2:18 AM

Содержание KD-MAX8x8

Страница 1: ...the video industry for Home Theater Retailers Custom Installers System Integrators Broadcasters Manufacturers and Consumers Key Digital Systems 521 East 3rd Street Mount Vernon NY 10553 Phone 914 667...

Страница 2: ...h up to 64 zones outputs Up to 16 sources inputs with up to 64 zones outputs Up to 24 sources inputs with up to 32 zones outputs Up to 32 sources inputs with up to 32 zones outputs Control Integration...

Страница 3: ...y set so that analog is the associated type If the associated input type is set to analog the output selecting the source will output the analog feed on both the analog and PCM output connectors The d...

Страница 4: ...53 phone 914 667 9700 fax 914 668 8666 Enterprise Software License for Compass Control Pro Supports iOS Android KD ProCL8 KD ProCL6 KD ProCL4 KD ProCL1 KD ProCL1 KD MC1000 Master Controller Zone 1 KD...

Страница 5: ...dio Type 1 L R 2 L R 3 Balanced 4 N C Matrix Switching Command Associated Audio IR Button Sequence Audio Mode X Y X Output 1 8 Y Input 1 8 Output Mute Un mute IR Button Sequence R1 X Mute Restore X Ou...

Страница 6: ...address is 192 168 1 239 with default port 23 Connection Protocol Baud Rate 57 600 bits per second Data Bits 8 Stop Bits 1 Parity None Flow Control None Carriage Return Required Notes Commands are no...

Страница 7: ...e format KD MAX8x8 STA Key Digital Systems STATUS KD MAX8x8 System Address 00 F W Version 1 0 Expansion Matrix Switch Input 08 Output 08 Unit Number 0 RS232 Baud Rate 057600bps Data 8bit Parity None S...

Страница 8: ...female for digital audio following SPDIF format IEC 60958 Supports sampling rate up to 192KHz Output each Balanced unbalanced line level audio on 6 pin terminal block Drives 2VRMS line audio input wi...

Страница 9: ...Power Supply Use You MUST use the Power Supply provided with your unit or you VOID the Key Digital Warranty and risk damage to your unit and associated equipment How to Contact Key Digital System Desi...

Страница 10: ...16 17 KD MAX8x8 Manual indd 16 17 12 23 17 2 18 AM...

Отзывы: