2
Quick Setup Guide
CONNECT:
Begin with the Tx and Rx units and all input/output devices turned off with power
cables removed
.
1.
Connect your HDMI source to the input port of the Tx unit
2.
Connect your HDMI display to the output port of the Rx unit
3.
Connect a CAT5e/6 cable between Tx and Rx unit . Use 568-B termination .
4.
Connect IR emitter from Tx or Rx unit to the IR receptor of the device you wish to control .
5.
Mount IR Sensor in a location that can easily collect line of sight IR signals from remotes .
Connect into the Tx or Rx unit’s IR In port .
»
If hard-wired, IR is needed couple IR Emitter from control system to IR sensor
6.
BEFORE
connecting power supply to power outlet, screw-in the power supply to the Tx or Rx unit
7.
AFTER
all connections are made, plug-in power supply to power outlet
8.
Power on source and display
CONFIGURE:
The default EDID handshake is 4Kx2K@60, 18G, HDR, 2ch audio (setting A) with 18G signal
bypass. Use the EDID rotary to choose desired handshake to provide to connected source and
the slide-switches to adjust 18G signal and hot plug detection handling.
Rack Mounting
In addition to mounting with the supplied L-Brackets, multiple KD-EX18G units may be mounted in
KD-SMS16 using the side mounting screws . KD-SMS16 is a mounting shelf for Key Digital units with
side mounting screw spacing of 2 .912”, 2 .582”, or 2 .252” .
›
Do NOT exceed 12 units as doing so will result in unit damage by overheating.