EDID Settings

 

The default EDID is ‘00’--Copy EDID from output 1.

0

Copy EDID from HDMI Output1

A

4Kx2K@60, 2CH AUDIO

1

1080i, 2CH AUDIO

B

4Kx2K@60, DOLBY/DTS 5.1

2

1080i, DOLBY/DTS 5.1

C

4Kx2K@60, HD AUDIO

3

1080i, HD AUDIO

D

1280x720p@60 DVI

4

1080p, 2CH AUDIO

E

1920x1080p@60 DVI

5

1080p, DOLBY/DTS 5.1

F

3840x2160p@30 DVI

6

1080p, HD AUDIO

* EDID (Extended display identification data) is a 

data structure provided by a display to describe its 

capabilities to a source device

7

4Kx2K@30, 2CH AUDIO

8

4Kx2K@30, DOLBY/DTS 5.1

9

4Kx2K@30, HD AUDIO

Hot Plug Control

The KD-1x8CSK allows modifying HPD (Hot Plug 
Detection) protocol between source and display.  
Modifying HPD protocol will allow overcoming HPD 
handshake incompatibility between source and 
display.  Modifying HPD protocol may also help fix other 
problems related to HDMI connectivity. Forcing HPD will 

also allow a source to output a signal even if no display is connected/detected.

RS-232 Commands

The KD-HD16x16ProK provides access to all functions when used with an RS-232 control 
system.
Connection protocol is as follows:

 

Baud Rate = 57600 bits per second

 

Data Bits = 8 

 

Stop Bits = 1

 

Parity = None

 

Flow Control = None

 

Carriage Return: Required

 

Line Feed: Required

Command Name

RS-232 Command

Description

Help

H

Provides list of all possible RS-232 commands 

Status

STA

Provides status of unit

Power On

PN

Sets unit power ON

Power Off

PF

Sets unit power OFF

Output xx ON/OFF

SPOxxON/OFF

Turns ON/OFF output xx

Example:

 To turn on output 6, send command 

SPO06ON

Example:

 To turn off output 8, send command 

SPO08OFF

Note:

 All outputs are on by default

Output xx Debug 
Mode

SPOxxDBGON/
OFF

Turns ON/OFF debug mode for output xx

Example:

 To turn on debug mode for output 

02, send command 

SPO02DBGON

Example:

 To turn off debug mode for 05, send 

command 

SPO05DBGOFF

Note: 

Debug mode is OFF for all outputs by 

default

Note: 

Output signals are active during debug 

mode

RS-232 Baud Rate

SPCRSBz

Sets unit baud rate to z.  z = 0-4 (0 = 57600,  
1 = 38400, 2 = 19200, 3 = 9600, 4 = 4800)

Note:

 Default baud rate is 57600

Reset to Factory 
Default

SPCDF

Resets unit to factory default settings

Pin 5 – Ground

Pin 3 – Receive

Pin 2 – Transmit

RS-232 cable pin out

KD-1x8CSK_Manual_5.25x7.5.indd   4-5

11/13/14   10:52 AM

Содержание Champion KD-1x8CSK

Страница 1: ... Web www keydigital com Key Digital led by digital video pioneer Mike Tsinberg develops and manufactures high quality cutting edge technology solutions for virtually all applications where high quality video imaging is important Key Digital is at the forefront of the video industry for Home Theater Retailers Custom Installers System Integrators Broadcasters Manufacturers and Consumers Rev 0 Nov 20...

Страница 2: ... Manages TMDS re clocking signal re generation HDCP source display authentication Hot Plug Management and EDID Control handshake Hot Plug Control Allows modifying HPD Hot Plug Detection protocol between source and display Lossless Compressed Digital Audio Dolby TrueHD Dolby Digital Plus and DTS HD Master Audio Deep Color Support Up to 12 bits color up to 8 bits color 4K 60 I2C Communication EDID a...

Страница 3: ...tible with the display devices Please reset the unit by either unplugging and plugging the HDMI connections or via a power cycle for the new settings to take effect Optional HDMI Cable clip included Rotary EDID Control Switch Quick Setup Guide Step 1 Find a safe and convenient location to mount or place your KD 1x8CSK unit Step 2 Begin with the KD 1x8CSK unit and all input output devices turned of...

Страница 4: ...n used with an RS 232 control system Connection protocol is as follows Baud Rate 57600 bits per second Data Bits 8 Stop Bits 1 Parity None Flow Control None Carriage Return Required Line Feed Required Command Name RS 232 Command Description Help H Provides list of all possible RS 232 commands Status STA Provides status of unit Power On PN Sets unit power ON Power Off PF Sets unit power OFF Output ...

Страница 5: ...r in hard to access spaces 3 If installing the unit into wall or mounting bracket into sheet rock provide proper screw support with bolts or sheet rock anchors Safety Instructions Please be sure to follow these instructions for safe operation of your unit 1 Read and follow all instructions 2 Heed all warnings 3 Do not use this device near water 4 Clean only with dry cloth 5 Install in accordance w...

Страница 6: ...pairs and Warranty Service Should your product require warranty service or repair please obtain a Key Digital Return Material Authorization RMA number by contacting us at Phone 914 667 9700 E mail rma keydigital com Feedback Please email any comments questions about the manual to E mail customersupport keydigital com Warranty Information All Key Digital products are built to high manufacturing sta...

Отзывы: