Page 5
sir_x_x_y
Addressing per
Command
x x = desired two-digit address for
command (01 – 99)
y = Input Select, Up, Down (1-4, 5, 6)
gir
Address Setting Status
dir_y
Delete Address Setting
per Command
y = Input Select, Up, Down (1-4, 5, 6)
½
All RS-232 commands must be in lower case letters, require spaces where indicated above with
( _ ), and require a carriage return to be sent.
Multiple KD-HDRV Unit Configurations
Up to 99 individually addressable units can be installed. KD-HDRV switchers allow you to assign a
two-digit address to each unit or each of the selectable inputs. This capability can be configured
via IR or the RS-232 port.
½
Addressing Buttons / Units via IR
»
With power enabled on the unit, press the “Power On” button. The “Input Select” LED
lights will begin to blink, indicating that the KD-HDRV unit is ready to receive the address
information.
»
Press the first digit (0 – 9) of the two-digit address. Once this first digit has been received
“Input Select 1” LED will blink.
»
Press the second digit (0 – 9) of the two-digit address. Once this second digit has been
received “Input Select 1” and “Input Select 2” LED’s will blink.
»
Press the Input Select button (Input 1 – Input 4, Up or Down) that you wish to assign the
two-digit address to. Once this is completed, all “Input Select” lights will become solid
indicating that the Input Select button has now been re-addressed.
»
Repeat Steps 2 through 4 if you wish to assign an address to additional “Input Select”
buttons or to your entire KD-HDRV unit.
»
Press “Power On” button to exit addressing mode when completed.
½
Addressing Buttons / Units via RS-232
»
See “RS-232 Commands and Protocol” section for RS-232 Addressing Commands
»
To address an Input, use “sir_x_x_y” command. To address an entire unit, repeat command
for each Input, Up, and Down
»
For address settings, use “gir” RS-232 command to receive a list of address settings
»
To delete address settings, issue “dir_y” RS-232 command