4.3 - Board display menu
The values displayed will be refreshed every second.
Code
Description
1
firmware release
2
selector status
0 = bidirectional
1 = partial opening
2 = internal radar
3 = free
4 = locked
5 = opening
6 = external radar
3
weight class
4
total count (cycles)
5
partial count (cycles), can be reset if above zero by pres-
sing
Canc
6
encoder position (steps)
7
travel stroke learnt (steps)
8
opening deceleration distance
9
closing deceleration distance
10
battery voltage (volts)
11
motor voltage (volts)
12
motor current for last operation (amps)
13
obstacle threshold (amps)
14
door status when error occurred
(error number and description)
J.
15
0
59
Voltage applied when door stopped
L.
0
0
2
FOTO Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
N.
0
0
2
FOTO RALL Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
O.
0
0
2
STOP Surveillance
0 = not monitored
1=one monitored device
2=two monitored devices
P.
0
0
1
Battery Test
0 = test disabled
1 = test enabled
R.
0
0
1
Lock if R.INT or R.EXT
0 = Normal functioning
1= RINT or REXT closed door locks
T.
0
0
1
Sixth manual selector position
(LOGO KEY)
0 = Partial opening
1=REXT(external radar active)
U.
0
0
9
Duration opening START
0 = step-step
1 to 9 (in tens of seconds)
Y.
0
0
1
Interlock
0 = disabled
1 = enabled
Keypad:
To quit the “Board parameters menu” and return to the
“Main Menu”, press
Exit
or
Esc
To confirm press
Ok
To scroll through the parameters press or
To modify the value of a parameter, press
+
or
–
To confirm modification of a parameter press
Ok
Keypad:
To quit the “Board display” menu and return to the
“Main Menu”, press
Exit
or
Esc
To scroll through the parameters press or
Errors:Reading error:
appears if it is not possible to establish
communication with the board.
Writing error:
appears if it is not possible to write a parameter on
the board.
Errors: Reading error
: appears if it is not possible to esta-
blish communication with the board.
Содержание 900EASY
Страница 26: ...26 26 NOTAS...
Страница 27: ...27 27 NOTAS...