Kett Riceter fg529 Скачать руководство пользователя страница 8

6

1

 

2

 

3

 

Take out the main unit 
from the carrying case.

Take out the batteries 
from under the battery 
holder.

Open the battery box 
on the back side of the 
main unit, and place 4 
batteries appropriately.

 How to Place Batteries

Note : Rice husker (TR-130) is included / not included depending on the model number. Above  example is fg501.

Содержание Riceter fg529

Страница 1: ...Grain and Seed Moisture Tester Riceter fg529 Operating Manual...

Страница 2: ...ter fg500 series This tester can measure the moisture of grain by simple op eration but proper operation is necessary for accurate moisture measure ment Please read this operating manual carefully bef...

Страница 3: ...1 Contents of Package 2 Part Names 3 Description of Display 4 How to Place Batteries 6 Before Measurement 7 Measurement 8 Average Value 18 Storage 19 Specifications 20 Table of contents...

Страница 4: ...tents of Package Maize mill Operating manual Rice husker TR 130 Carrying case Sample tray 2 pcs Spoon with tweezers Cleaning brush Battery AA sizex4 pcs Inspection certificate Riceter J m f checker Op...

Страница 5: ...3 Part Names Note Application table differ depending on the model number POWER button SELECT button Display Handle stop red mark Model No MEA button Measure AVG button Average Testing Chamber Handle...

Страница 6: ...ally turned off in approx 5 minutes after turning on the power if no operation is performed Use of backlight in the display section allows users to see the display clearly even in the dark Battery Ind...

Страница 7: ...ell below the lower limit of the measurement range or the contact between the test sample tray and the measuring unit of the main body was poor Error mark Main unit temperature is too low 5 C or lower...

Страница 8: ...t the batteries from under the battery holder Open the battery box on the back side of the main unit and place 4 batteries appropriately How to Place Batteries Note Rice husker TR 130 is included not...

Страница 9: ...re gradually discharging even when the tester is not used It is recommended to always use new batteries Place batteries in the correct polarity Riceter fg500 series is equipped with a temperature comp...

Страница 10: ...s the POWER button All the characters and marks on the display section as well as the backlight light up for 2 seconds and then model number and software version number are automatically displayed The...

Страница 11: ...n d Application Times are displayed It is ready for measurement Measurement Press the SELECT button and repeat until the abbreviation for the name of the application you wish to test appears The sele...

Страница 12: ...eat Jute seed Parboiled rice and Atap rice See page 13 3 B for Maize milled Lentil Mustard Sesame Chili Black cumin and Onion See page 13 3 C for Mung bean and Black gram See page 14 3 D for Grass pea...

Страница 13: ...evenly in one layer on the sample tray Note Both the amount of sample is too much or insufficient may cause a measurement error Over more too much sample may cause wear on the screw and damage the in...

Страница 14: ...e one cup of sample by using the spoon with tweezers and put it on sample tray Note The milling operation of Maze is included in the attached manual 3 B 1 Mung bean and Black gram Take one and a half...

Страница 15: ...move the handle insert the sample tray into the testing chamber until the guide line is hidden place 5 to 6 pieces of grain through the threaded opening in the front of the unit and attach the handle...

Страница 16: ...g chamber and insert it into the testing chamber until the guide line is hidden Note Failure to observe this may cause the tip of the handle to damage the plastic portion of the sample tray Be sure to...

Страница 17: ...e MEA button the decimal point blinks the backlight lights up the moisture content and measuring number are displayed thereafter The backlight goes out after 4 seconds but the moisture content remains...

Страница 18: ...The measuring count alsochangesatthesametime 7 After a lapse of 5 minutes the power is automatically turned off and all the displayed items are cleared Pressing the POWER button while the display is i...

Страница 19: ...e after every measurement If the last test sample remains proper measurement cannot be performed For continuous measurement disconnect the handle and remove the attached sample and contamination from...

Страница 20: ...btain the average value of m o i s tu r e co nte nt s p r e ss th e AVG button within 5 minutes after measurement After the last measured value disappears the average calculation function does not wor...

Страница 21: ...lean every portion of the main body in a careful manner Especially for the measuring unit disconnect the handle and clean the inner contact section sufficiently Be sure to put the tester together with...

Страница 22: ...STA 103 C 4 5g whole 17hrs 7 Maize M A I Z 9 0 30 0 0 5 9 20 BG DAE 135 C 2g grinding 1hr 8 Parboiled rice P E R B 9 0 20 0 0 5 9 20 BG DAE 135 C 2g grinding 1hr 9 Atap rice A T A P 9 0 20 0 0 5 9 20...

Страница 23: ...2 Reference method 16 Oil seeds Mustard seed MUST 5 0 18 0 1 5 5 18 ISO 665 2000 E 103 C 5 10g whole constant 3 hrs 17 Sesame S E S A 5 0 18 0 1 5 5 18 ISO 665 2000 E 103 C 5 10g whole constant 3 hrs...

Страница 24: ...20 moisture range of sample Power source 1 5V AA size battery x 4 Auto power off 5 min after nothing of operation Power consumption Max 0 3W Dimensions and weight 164 W x 94 D x 64 5 H mm 0 44kg appro...

Страница 25: ...23...

Страница 26: ......

Страница 27: ......

Страница 28: ...cted in this user manual may not ap pear exactly as their actual counterparts but this does not affect their operation or functionality This user manual was intended to be written as clearly and accur...

Отзывы: