Kett KH-70 Скачать руководство пользователя страница 2

060046

THIN MATERIALS

For single materials, thinner than 10 mm, 
the sensitivity of the meter is normally 
n o t   e n o u g h .   H o w e v e r,   c o m p a r i n g 
measurements to determine wet spots in 
the material can still be performed.

To obtain a more accurate measuring result 
we recommend measurements in a pile 
without air spaces between the single parts 
and with a minimum thickness of 20 mm 
for the pile.

BASE

With material thickness < 50 mm the base 
material is very important.
Avoid a metal base. The best results are 
achieved if the material to be measured is 
hold into the air. Polystyrene material with 
a minimum thickness of 20 mm can also be 
used.

WET SURFACES

In case of material with wet surface a PVC-
foil can be used between the material and 
measuring springs electrodes.

REFERENCE MEASUREMENT

How to locate wet spots:
1.  Set the Material code to C1 or P1
2.  Hold the spring electrodes to a surface 

you know is dry

3.  The received value corresponds to a “dry 

material” and could be used as reference 
value

4.  Now it is possible to locate moist and 

leakage using the reference value

5.  By moving the measurement springs 

over the surface you could quickly 
locate the leakage and find out about 
the extent of the moist damage

TECHNICAL SPECIFICATIONS

Measuring method High frequency 

dielectric constant 
measurement

Measuring range 
Paper materials

0-30 % moisture 
content (H2O)

Measuring range 
Cardboard

0-175% moisture 
content (H2O)

Working conditions, 
temp/ RH

-10 to +60° C / 0 - 90 %
(non condensing)

Accuracy

+/- 2%

Resolution

0,1%

Field penetration 
depth

Approx.. 50 mm

Max. storage 
temperature

-20 to +60°C

Power supply

9 V alkali battery

Display

LCD digital

Dimensions

150 x 72 x 25 mm

Weight approx.

150 g. incl. battery

Housing material

ABS

Sensor material

Chrome plated steel

Carrying case

Soft

 

Отзывы: