7

4. DISPLAY SCREEN

Number

Battery information

Measurement times

HAY display

Alarm setting

Moisture %

Bar graph

Содержание HX-700

Страница 1: ...HAY MOISTURE TESTER HX 700 Operating Manual...

Страница 2: ...PRECAUTIONS Read all the safety precautions in this manual DO NOT USE THE INSTRUMENT IF A FAILURE HAS OCCURRED Call for repair or service if a failure or a malfunction has been observed Contact our s...

Страница 3: ...W TO USE THE INSTRUMENT 8 5 1 Preparation for measurement 8 5 2 How to measure 9 5 3 Precautions for measurement 11 5 4 Display of the average 12 5 5 How to set Continuous Measurement mode 13 5 6 How...

Страница 4: ...n of the hay due to water content is an important issue in business transactions HX 700 is a long weighted instrument designed to match the needs of this industry Make the most of the advantages offer...

Страница 5: ...lay Digital LCD The smallest display digit is 0 1 Usable temperature 0 C 40 C 32F 104 F Special features Average display Upper alarm setting 10 39 or off Automatic power off in 5 minutes Moisture corr...

Страница 6: ...3 NOMENCLATURE Instrument body Accessories Connector Battery compartment cover on the back Display screen Operation panel Probe Operating manual 1 5V AA alkaline battery x 6 Carrying case Shoulder str...

Страница 7: ...7 4 DISPLAY SCREEN Number Battery information Measurement times HAY display Alarm setting Moisture Bar graph...

Страница 8: ...ent door and install the batteries Take care not to reverse the polarity of the batteries Replace the cover When the batteries are worn will blink on the display screen Change all batteries at the sam...

Страница 9: ...it After that HAY TIMES and will be displayed If the LCD wouldn t start up as described here there might be an error occurring in the instrument Refer to 6 Error display 2 Insert the probe in the hay...

Страница 10: ...is out of the range HI for exceeding and LO for lower than will be displayed 4 Pull the probe out of the hay The last moisture will remain displayed To continue the measurement insert the probe again...

Страница 11: ...measurement 1 Insert the probe at the outer surface of the hay roll Other ways of measurement may result in errors 2 If it is difficult to insert try other angles or make a hole with a sharp stick bef...

Страница 12: ...verage After measurement has been done 2 9 times you can display the average by pressing the key The key will display AVE Calculated average and Measurement times After 9 times the Measurement times d...

Страница 13: ...e sample moisture is lower than the measurement range 2 To release the continuous measurement mode Press the key for more than 2 seconds until a short beep is heard the display will be off for a momen...

Страница 14: ...e In such cases the moisture display can accept a bias correction 9 9 9 9 described as follows 1 Press the key BIAS on the display will blink and display the corrected value which was last entered 0 0...

Страница 15: ...is over the limit 1 Press the key The number to the right of ALARM will blink 2 Enter the limit value Enter 2 digit number of the limit Press the and key to enter 20 for instance 3 Press the or the ke...

Страница 16: ...r in the measurement conditions either of the following messages will appear for 4 seconds before turning the power off automatically 1 The temperature sensor has an error Call for repair 2 The electr...

Страница 17: ...s 5 C 23 F or lower Warm the instrument up to the usable ambient temperature range 0 40 C 32 104 F 4 The instrument temperature is 50 C 122 F or higher Cool down the instrument to the usable ambient t...

Страница 18: ...MEMO...

Страница 19: ......

Страница 20: ...0809 PA 0102 100...