BoiLer ConTroLs

operation

note

. The pump will operate briefly as a self-check once every 24 

hours, regardless of system demand.

Control of water temperature

The boiler controls the central heating radiator temperature to 

a maximum of 80

o

C, adjustable via the CH temperature control 

(A) or is automatically set by the weather compensation device 

provided, the potentiometer adjusts the heating slope.

The Keston System is a high efficiency condensing boiler which is 

most efficient when operating in condensing mode.

The boiler will operate in this mode if the CH temperature control 

(A) is set to the ‘e’ position (economy mode).  This control should 

be set to maximum for very cold periods

to shut down the boiler

Set the mode control knob to OFF.

To relight the boiler

Repeat the procedure detailed in ‘To light the boiler’.

Frost protection

If no system frost protection is provided and frost is likely during 

a short absence from home, leave the heating controls (if fitted) 

at a reduced temperature setting. For longer periods, the entire 

system should be drained.
If the system includes a frost thermostat then, during cold 

weather, the boiler should be turned OFF at the time switch (if 

fitted) ONLY. The mains supply should be left switched ON, with 

the boiler thermostat left in the normal running position.

Boiler overheat Protection

The boiler controls will shut down the boiler in the event of 

overheating.  Should this occur, a fault code   will be displayed.
Refer to fault chart.

Flame Failure

Should this occur a fault code 

 will be displayed. Refer to fault 

chart.

Loss of system water pressure

The gauge (E) indicates the central heating system pressure. If the 

pressure is seen to fall below the original installation pressure of 1-2 

bar over a period of time then a water leak may be indicated. In this 

event conduct the re-pressurising procedure as follows:

Re-pressurise via the filling loop to 1 bar (if unsure contact your 

installer), turn off the tap on the filling loop and turn switch (B) to the 

reset position and then back on again to reset the boiler.

If unable to do so or if the pressure continues to drop after filling a 

Gas Safe Registered Engineer or in IE a Registered Gas Installer 

(RGII) should be consulted.  

noTe. The BoiLer WiLL noT oPeraTe iF Pressure has 

rEDUCED to LESS tHAn 0.3 BAr UnDEr tHIS ConDItIon.

Condensate Drain

The condensate drain (F) must not be modified or blocked. 

Blockage of the condensate drain, caused by debris or freezing, can 

cause automatic shutdown of the boiler.
If freezing is suspected and the pipe run is accessible an attempt 

may be made to free the obstruction by pouring hot water over the 

exposed pipe and clearing any blockage from the end of the pipe. 

If this fails to remedy the problem the assistance of a Gas Safe 

Registered Engineer or in IE a Registered Gas Installer (RGII) 
should be sought.

Escape of gas

Should a gas leak or fault be suspected contact the National Gas 

Emergency Service without delay. 

Telephone 0800 111 999

Do not search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth. 
To remove stubborn marks and stains, wipe with a damp cloth and 

finish off with a dry cloth. 

Do not use abrasive cleaning materials.

maintenance

The appliance should be serviced at least once a year by a Gas 

Safe Registered Engineer or in IE a Registered Gas Installer (RGII).