2

Only use this display
– in a way according to its

intended purpose

– if its technical condition is 

perfect

– adhering to the operating

instructions and the general
safety instructions.

!

2 Safety instructions and warnings

1. Before carrying out any installation or maintenance

work, make sure that the power supply of the digital
display is switched off.

2. Only use this digital display in a way according to its

intended purpose. 

3. If its technical condition is perfect.
4. Adhering to the operating instructions and the gene-

ral safety instructions.

5. Adhere to country or user specific regulations.
6. The digital display is not intended for use in areas

with risks of explosion and in the branches excluded
by the standard EN 61010 Part 1.

7. The digital display shall only operate if it has been

correctly mounted in a panel, in accordance with the
chapter “Main technical features”.

This digital display is an easy-to-use, microprocessor-
controlled device for the display (and the acquisition) of
measured temperature values. The temperatures are
measured by means of Pt100 or Ni100 resistance ther-
mometers. They can display either the current measu-
red value, the maximum value or the minimum value. In
case of power switch-off, the maximum and minimum
values are stored in an EEPROM. The values are
restored as soon as the display is powered again. The
Latch input is isolated electrically from the signal input
by means of an optocoupler. It allows storing the cur-
rent measured value.
The supply voltage (10 .. 30 V DC) is isolated electri-
cally from the signal input by means of a DC/DC con-
verter.

1 Short description

The digital display only may be used as a panel-moun-
ted device. Applications of this product may be found in
industrial processes and controls, in the branch of the
manufacturing lines for the metal, wood, plastics,
paper, glass, textile, etc., processing industries. 
Overvoltages at the terminals of the digital display must
be limited to the values of overvoltage category II.

If the digital display is used to monitor machines or pro-
cesses in which, in case of a failure of the device or an
error made by the operator, there might be risks of
damaging the machine or causing accidents to the ope-
rators, it is up to you to take appropriate safety measu-
res.

2.1 Use according to the intended purpose

Содержание 531K

Страница 1: ...K Process Display Temperature display for Pt100 and Ni100 RTD s 99905 10 20 03 KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 935 1320 Fax 732 935 9344 Installation...

Страница 2: ......

Страница 3: ...parameter setting 4 5 4 Programming 5 5 5 End of programming 6 6 Operation 7 6 1 Switching the display during operation 7 6 2 Saving the momentary value 7 7 Error and alarm messages 7 8 General techni...

Страница 4: ...eans of Pt100 or Ni100 resistance ther mometers They can display either the current measu red value the maximum value or the minimum value In case of power switch off the maximum and minimum values ar...

Страница 5: ...ommend the use of wire end ferrules in order to avoid short circuits between adjacent terminals 3 In order to keep the interferences at the measuring input as low as possible the signal and power sup...

Страница 6: ...and switching to the following parameter 2 and press simultaneously the right grey key 5 2 Changing the parameter setting 1 press the right hand grey key to change the parameter setting by one value a...

Страница 7: ...yed result will not be correct 5 4 3 Decimal point Decimal point Resolution 0 1 C 0 1 F Resolution 1 C 1 F 5 4 4 Temperature unit Selection in the menu Display in C Display in F 5 4 5 Correction value...

Страница 8: ...mum value The maximum value can be reset using the red key The maximum value cannot be reset 5 4 7 Minimum value acquisition The minimum value may be saved and consulted during operation see 6 1 Minim...

Страница 9: ...once to display the designation of the active display function for 2 seconds If during this time the right hand grey key is pressed a second 6 1 Switching the display during operation time the displa...

Страница 10: ...ole measuring range at an ambient temperature of 20 C Linearity error Ni100 0 2 for the whole measuring range at an ambient temperature of 20 C Temperature drift 0 1 K Kambient Measuring rate 5 measur...

Страница 11: ...nce EN 61000 6 2 Operating temperature 20 C 65 C relative humidity 85 Storage temperature 25 C 70 C 9 Scope of delivery Digital display Clamp Front panel for clamp mounting Panel cut out 50 x 25 mm Fr...

Страница 12: ...nsions Countersinking Af3 DIN 74 1 Panel cut out Mounting frame Panel cut out Connections 1 10 30 V DC Supply voltage 2 0 V DC GND 3 Latch Input 4 Pt100 Ni100 5 Pt100 Ni100 Sensor input 6 Pt100 Ni100...

Отзывы: