EN
Display text
PFC
1
Possible cause
Remedial measure
|Power outage|
-
Power supply has failed.
The unit’s miniature fuse has
tripped.
Power supply has failed, circuit
breaker has tripped.
Main switch is defective - mains
supply cable interrupted.
none - general power outage.
Check fuse.
Check main switch.
Check mains cable.
Deliberate switching off, shut down
the control unit (
|Temperature error 1a
or
2a|
E
Self-resetting temperature monitor-
ing has tripped.
Self-resetting - the pump starts again
automatically when the motor has
cooled down. The error message is
acknowledged automatically. Have
the pump replaced if the temperature
error occurs frequently.
|Temperature error 1b
or 2b|
E
NON self-resetting temperature
monitoring has tripped.
NON self-resetting - the pump
remains inactive, even after the motor
has cooled down. It is necessary to
switch off and switch on again the
control unit. Have the pump replaced
if the temperature error occurs fre-
quently.
|Level error|
E
Incorrect layout or wiring of the
probes
The sensors in the control unit are
configured incorrectly,
Functional check as described in the
system documentation.
70 / 124
Installation and operating instructions
010-532_02_SON
Содержание Aqualift Comfort 400V Duo
Страница 23: ...Zusatzmodul Sanftstart Sanftstopp IL 3RW40 DE 010 532_02_SON Einbau und Betriebsanleitung 23 124 ...
Страница 24: ...DE Zusatzmodul Frequenzumrichter IL Frequenz 24 124 Einbau und Betriebsanleitung 010 532_02_SON ...
Страница 41: ...010 532_02_SON 41 124 ...
Страница 103: ...Dodatkowy moduł łagodnego rozruchu zatrzymania IL 3RW40 PL 010 532_02_SON Instrukcja zabudowy i obsługi 103 124 ...
Страница 104: ...PL Dodatkowy moduł przetwornicy częstotliwości częstotliwość IL 104 124 Instrukcja zabudowy i obsługi 010 532_02_SON ...
Страница 123: ...010 532_02_SON 123 124 ...