Mähraupe HyCut
Malfunctions / Troubleshooting
DE
2021-01-27
57 / 65
8
Malfunctions / Troubleshooting
The following chapter describes possible causes for malfunctions and the steps
that must be taken to remedy them.
If malfunctions occur repeatedly, shorten the maintenance intervals according to
the actual load.
If you experience a malfunction that cannot be remedied by the information
provided, contact the manufacturer.
8.1
Safety instructions
Observe all safety instructions provided in the Safety chapter!
(See Chapter 2 Safety on Page 7)
8.2
Warning codes
In order to alert the operator of a borderline operating situation, the lights are
activated in a specific pattern (code), e.g. they will flash.
Pattern
Meaning
Quick flashing
Load management active
Quick flashing
Tilting of the tracked mower in the limit area
Slow flashing and horn signal
Failure (collective error message)
8.3
Causes of malfunctions and how to remedy them
This chapter describes the most common malfunctions that can occur while the
tracked mower is in operation in more detail. For malfunctions that require a major
intervention, always have the repair work carried out by a specialist workshop.
8.4
Petrol engine malfunction table
Malfunction
Possible causes
Remedy
The petrol engine does not
start
Spark plug connector not attached
Attach the spark plug connector
Fuel tank empty or incorrect fuel
used
Fill the fuel tank with fresh fuel
Fuel line blocked
Clean the fuel line, change the fuel
filter
Spark plug defective
Replace the spark plug
Too much fuel in the engine
(flooded)
Dismantle the spark plug, dry/clean it,
put it back in place and restart the
engine