KERR Highlander TW-2000 Скачать руководство пользователя страница 38

 

Terms and Conditions of Warranty 

 

1)  The warranty is not assignable and rights 

pursuant to it are given only to the original 
purchaser of the furnace from an authorized 
retailer. 

 
2)  The warranty is null and void unless the 

original purchaser fully completes the 
warranty registration card and the card is 
received by Kerr Heating Products within 30 
(thirty) days after installation of the furnace. 

 
3)  The warranty applies only to defects in the 

heat exchanger resulting from defective 
material and/or workmanship and the rights 
of the purchaser as to claims resulting from 
defects in other parts or accessories of the 
boiler supplied by suppliers or manufacturers 
other than Kerr are limited to the rights, if 
any, which a purchaser has against such 
other manufacturer or supplier and the 
warranty does not apply to any heat 
exchanger, parts or accessories which must 
be repaired or replaced for any reason other 
than as aforesaid including fire, flood, act of 
God or other cause. 

 
4)  The warranty of the heat exchanger against 

defects of material and/or workmanship is 
limited to its repair or replacement f.o.b. Kerr 
Heating Products, Parrsboro, Nova Scotia 
provided such defect is in the sole opinion of 
Kerr, the result of defective materials and/or 
workmanship and not the result of others 
carelessness or failure to erect, install, 
operate or maintain the boiler in accordance 
with the written instructions of Kerr.  The cost 
of any labour for the removal or replacement 
of defective parts shall be the responsibility 
of the purchaser and  Kerr shall be 
responsible only for the cost of repairing or 
replacing the defective part f.o.b. Kerr 
Heating Products, Parrsboro, Nova Scotia.   

 

 
 
 
 
 

 
 
 

5)  Without restricting the generality of condition 

4 hereof, a boiler which is permanently 
distorted as a result of burning out of control 
is not to be considered to be defective in 
material or workmanship and is specifically 
exempted from coverage under the warranty. 

 
6)  Damage to the furnace or any part or 

accessory from abuse, misuse, overfiring or 
improper installation, or any boiler which has 
been altered or used in connection with third 
party equipment or materials is specifically 
excepted from coverage under this warranty. 

 

7)  The warranty of the repaired or replaced 

heat exchanger is limited to the period of the 
unexpired portion of the original warranty. 

 

8)  No boiler or part thereof shall be returned to 

Kerr except pursuant to Kerr’s written 
authorization. 

 

9)  Except to the extent of the cost to the repair 

or replacement of the heat exchanger in 
accordance with the terms and conditions 
hereof Kerr shall not be liable for any direct, 
special, secondary, indirect, incidental or 
consequential damages resulting from failure 
to perform its obligations hereunder, or part 
or failure to perform function of any boiler or 
any part or for any cause beyond its control, 
including without limitation, fire, flood, strike, 
weather, impossible roads, labour 
disturbance, accident, shortages or labour, 
parts, material, acts of God, or 
Governmental authorities. 

 

10)  The exclusive remedy of the purchaser is as 

set forth herein and there are no 
representations, warranties, collateral 
agreements, or conditions affecting the sale 
and Kerr makes no warranty of 
merchantability or of fitness for any purpose 
and there is no warranty either expressed or 
implied beyond that set forth herein. 

 

 
 

 

WARRANTY REGISTRATION CARD

  - 

This card must be filled in and mailed within 30 days. 

Name of Purchaser:  _______________________________________________________________________________________ 
Installed at (Street & Number):  _______________________________________________________________________________ 
City, Province/State & Postal/Zip Code:  ________________________________________________________________________ 
Name of Installer:  _________________________________________________________________________________________ 
Installer’s Address: _________________________________________________________________________________________ 
Date Installed:  ___________________________   Model Number:  _______________   Serial Number:  _____________________ 
This installation is for: 

 

_  New Home  

 

 

_  Existing Home  

 

 

 

If replacement, make and type of previous heating system:   

_  Oil      _  Wood       _  Electric       _  Gas 

 

How did you find out about Kerr furnaces or boilers:  _Television  _  Magazine  _ Newspaper  _ From a Friend     
_  Recommendation form Kerr Dealer 

 _ Radio  _Internet  _ Other (please specify):  ___________________________________ 

 
Purchaser’s Signature:  ______________________________________________  Date:  _________________________________ 

 
 
 

 

Содержание Highlander TW-2000

Страница 1: ...ORE INSTALLING BOILER OR LIGHTING FIRE CONSULT LOCAL AUTHORITIES IF IN DOUBT ABOUT YOUR LOCAL FIRE SAFETY REGULATIONS ALL INSTALLATIONS MUST BE MADE IN ACCORDANCE WITH LOCAL AND STATE OR PROVINCIAL CO...

Страница 2: ...rol System 13 2 8 Wiring 14 2 9 Dealer Instructions to Homeowner 14 2 10 Installers Checklist 15 2 11 TW 2000 Parallel Plumbing Wiring Explanation 15 DIAGRAMS TW 1 Parallel Piping Diagram TW 1EH Paral...

Страница 3: ...Rating Volts 120 15Amps Expansion Tank Size recommended 12 Dia X 36 min size NOTE Keep this manual in a safe place for future reference Follow manual carefully for the correct way to install and oper...

Страница 4: ...s of wood on warmer days WARNING DO NOT use chemicals or fluids to start the fire or during operation DO NOT burn driftwood or manufactured logs compressed wood Before adding fuel to an existing fire...

Страница 5: ...of creosote to form To reduce creosote build up during periods of low heat requirements i e Spring and Fall it is recommended to fuel the Wood Fired Boiler with smaller quantities of smaller diameter...

Страница 6: ...of build up on the heat exchanger or 3 inches of ash in the base If the wood boiler is to be left unused for an extended period of time more than one month then the appliance should be cleaned of all...

Страница 7: ...um opening of the combustion air damper is preset at the factory DO NOT adjust the stop or attempt to increase the combustion air by any means 1 7 ELECTRICAL POWER FAILURE If no one is home during a p...

Страница 8: ...g may result h This unit is NOT suitable for automatic stoking i Load carefully Do not slam fuel against rear or sides of firebox This may damage the brick lining See fig TW 7 to order and install rep...

Страница 9: ...Fire Underwriters and the C S A Standards for solid fuel burning equipment as outlined in B365 01 In all cases consult your local authorities and fire insurance company for specific regulations 2 2 UN...

Страница 10: ...in the basement These blocks should extend approximately 1 on all sides of the boiler to support the cabinet Continue as follows 1 Plan all plumbing and electrical runs so that flue pipe is easily rem...

Страница 11: ...or more per foot from the Boiler to the flue NEVER ALLOW THE SMOKE PIPE TO RUN DOWNHILL TO THE FLUE The smoke pipe and chimney should be at least 7 inches in diameter The flue pipe or a chimney may be...

Страница 12: ...d fuel is used the flue pipe from the smallest appliance shall be on top downstream ii If different fuels are used as permitted in Clause 5 2 7 the oil flue pipe shall be on top downstream and the sol...

Страница 13: ...vessel The relief valve included is threaded into the top of the pressure vessel and copper pipe is installed from its exhaust to the flange above the loading door on the firebox In addition to its a...

Страница 14: ...accounts for the 10 F differential of the triple aquastat Heating systems that require lower temperatures such as cast iron radiators and radiant systems require some form of mixing device to ensure t...

Страница 15: ...level no higher than center of door 5 Remove ash regularly as directed 6 Watch for soot build up in smoke pipe 7 Realize the danger of extreme overheating due to overfiring 8 Danger of flue fire if p...

Страница 16: ...tion chamber 4 Is the system full of water and air eliminated 5 Are zone valves and piping located to prevented drips on controls WIRING INSPECTION 1 Is main disconnecting switch within view 2 Wiring...

Страница 17: ...boiler triple aquastat which starts the primary circulator Metal 200 F Brass 190 F e Double Aquastat White Rodgers 1161 12 Low Limit Right This is used to maintain the wood boiler at the set temperat...

Страница 18: ...W 2000 8 Door Handle With Spring Not Shown TW 2000 9 Door Handle Cast Catch Not Shown TW 2000 10 Damper Door With Hinge Rod Not Shown TW 2000 11 K 26 Domestic Hot Water Coil Optional TW 2000 12 Coil G...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ...from coverage under this warranty 7 The warranty of the repaired or replaced heat exchanger is limited to the period of the unexpired portion of the original warranty 8 No boiler or part thereof shall...

Страница 39: ...er called the boiler against defects of materials and or workmanship appearing within a period of five years from date of installation All other parts and accessories of the boiler in accordance with...

Отзывы: