Customer Responsibilities
Kerotest Electrofusion Processors
are reliable, easy-to-use, rugged tools designed to withstand the conditions
found at construction sites around the world. With proper care, your processor will perform for many years.
Here are some general guidelines that should be followed to extend the life of your processor and keep it in
warranty:
Shannon
Portafuse III
Kerotest Electrofusion Processors
are splash resistant,
NOT WATERPROOF
. They should be stored in a
clean, dry environment.
DO NOT STORE THE PROCESSORS OUTSIDE. DO NOT WASH THE PROCESSORS
WITH A HOSE.
The enclosures are very durable and shock resistant; however, do not subject the processors to any
unnecessary shocks or stresses including but not limited to:
•
Tossing the processor into or out of a vehicle
•
Dropping the processor
•
Dragging the processor by the cables or leads
N/A
Fully charge the battery pack after each day
’
s use.
N/A
When not in use, recharge the battery pack at least once per
month. It is recommended that the battery pack be left on
charge when not in use.
N/A
Turn the processor OFF after each use to prevent the batteries
from discharging. It is recommended that the battery pigtail be
disconnected after use to ensure the unit is not accidentally
turned ON.
LEAVING THE PROCESSOR ON WHILE IN STORAGE
WILL DESTROY THE BATTERY PACK. THIS IS CONSIDERED
CUSTOMER ABUSE AND IS NOT COVERED UNDER WARRANTY.
Subscribe to the recommended calibration service offered by the manufacturer (see page 18).
Kerotest Electrofusion Processors
provide the proper outputs for a complete fusion based on the inputs
received from a scanned barcode (in Barcode Mode) or from the operator (in one of the alternate fusion
modes).
Whenever possible, Barcode Mode should be used.
Always scan the fitting manufacturer
’
s barcode affixed directly to the fitting about to be fused. If this barcode
is missing or damaged to the point it cannot be scanned, use the barcode from an
identical
fitting made by the
same manufacturer.
UNDER NO CIRCUMSTANCES SHOULD THE BARCODE FROM A SIMILAR FITTING BE USED.
Содержание Shannon Portafuse III
Страница 1: ......
Страница 2: ......
Страница 59: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 57 of 60 Page Intentionally Left Blank ...
Страница 60: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 58 of 60 Page Intentionally Left Blank ...
Страница 61: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 59 of 60 Page Intentionally Left Blank ...
Страница 62: ...Kerotest Manufacturing SHANNON PAF III OPERATORS MANUAL REV 3 Page 60 of 60 Page Intentionally Left Blank ...
Страница 63: ......