1.
Cooktop
2.
Aspirator
3.
Electrical ventilator
4.
Ventilation Opening
INSTALLATION OF THE HOB IN THE COUNTER
In order to prevent insertion of particles and liquids
between the hob and the counter attach the gasket on
the hob without allowing any overlapping before the
installation. (Figure 7)
Place the hob in the middle of the hole.
Secure the unit on the counter by using the installation
sheet and screws. (Figure 7 and 8)
•
Electric connection should be conducted by a competent and authorized person.
•
The electric cable of your hob should not be laid in hot places.
•
When the power cable is damaged, it should replaced by the authorized service dealer.
•
No reducer, adapter, and switch should be used for electrical connection since it will cause excessive
heat and fire.
•
Plug the electric cable to a grounded wall socket. The manufacturer cannot be held responsible if you
fail to do so.
•
The supply data of the electric network should be suitable with the data on the type label of the unit.
These instructions are prepared for specialist personnel having required competence. Installation of the
equipment should be suitable as per the applicable standards. All gas related works should be conducted when
the electric connection was cut. The value plate on the hob indicates the gas type intended to be used for use
with the hob. Connection to the gas supply (mains or gas canister) should be done after adjusting the hob to
the intended supply type. Note that the LPG hoods should have TSE stamp and 300 mmSS (30mbar) outlet
pressure. Natural gas pressure is 200 mmSS (20mbar). Please consult the authorized service for conversion
to natural gas or LPG. Use only piping, gaskets or seal as per the applicable national standards.
In some countries where conic connections are obligatory, conic connection is provided. In such a case the
conic connection part should be connected to the unit. If the unit will be connected to a flexible hose, the length
of the hose shall not exceed 120 cm.
Before starting works related to gas installation, please cut the gas supply. Make the connection so that no
pressure will be applied on the connection nuts and piping. Make sure that the pipe will not cause any clogging
or contact with the sharp corners. Note that the gas hose should be TSE certified and not be laid through hot
areas.
Make sure that no additional weight to be applied on the gas hose.
Figure 7.
Installation Clamp
Figure 8.