background image

20 

   

 

MAP-BA-e-1212 

 

7.1  Operating modes 

 

The device is in real mode at delivery. Use the mode key to switch over the device 
to the following operating modes. 

 

Operating mode 

Display 

Function 

Real time mode 

 

Shows current strength. 

 

 

 

 

Counting mode 

 

Counts number of gripping actions 
exceeding a previously set strength 
limit. 

 

 

 

 

Average mode 

 

Calculates the average strength  
derived from two hand grips 

 

 

 

 

Peak/Max Mode 

 

Shows max strength of hand grip. 

 
 

Содержание PROMAT MAP 130K1

Страница 1: ...Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating instructions Hand Grip Dynamometer KERN MAP Version 1 2 08 2012 G...

Страница 2: ...ter Table of Contents 1 Technical Data 3 2 Appliance overview 8 3 Basic Information General 9 4 Basic Safety Precautions 10 5 Transportation Storage 10 6 Removing packaging and initial start up 11 7 O...

Страница 3: ...ability d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of ai...

Страница 4: ...bility d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of air...

Страница 5: ...d 0 1 kg 0 2 lb Units kg lb Auto Off After 1 min without change of load Electric Supply 1 x CR2450 Service life 53 h Operating temperature 5 C 35 C Storage temperature 20 C 60 C Humidity of air max 8...

Страница 6: ...6 MAP BA e 1212 1 1 Dimensions MAP 80K1S...

Страница 7: ...MAP BA e 1212 7 MAP 80K1 MAP 130K1...

Страница 8: ...8 MAP BA e 1212 2 Appliance overview 1 Battery compartment see chapter 7 2 Display see chapter 8 3 Keyboard see chapter 8 4 Spring set see chapter 7 Transport case...

Страница 9: ...ettings Other areas of use must be released by KERN in writing Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the des...

Страница 10: ...nal document in German Staff training The medical staff must apply and follow the operating instruc tions for proper use and care of the product 5 Transportation Storage Testing upon acceptance When r...

Страница 11: ...me dampness for longer periods of time Non permitted condensation condensa tion of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment If present...

Страница 12: ...1212 How to replace a spring set 1 Press device until the two screws 1 become visible 2 Remove screws 3 Remove grip first followed by springs 4 Insert desired spring set 5 Reassemble device in revers...

Страница 13: ...MAP BA e 1212 13 Install two additional washers only in the 130 kg spring set s fig...

Страница 14: ...save battery power the device auto disconnects automati cally after 60 seconds have passed without a change of display If the batteries are run down soon LO appears in the display Replace battery If...

Страница 15: ...MAP BA e 1212 15 Commissioning Correct left hand right hand...

Страница 16: ...16 MAP BA e 1212 Correct left hand right hand...

Страница 17: ...MAP BA e 1212 17 wrong...

Страница 18: ...bility display 2 Battery status 3 Operation modus 4 Percentage display 5 Weighing unit lb 6 Weighing unit kg Keyboard overview Button Function Zero Switch on off zeroing Mode Select operating mode Set...

Страница 19: ...ero key Zero display appears If the device does not exactly show zero unload the device and press the zero key To switch off keep zero key pressed for approx 3 seconds During power up the device will...

Страница 20: ...ice to the following operating modes Operating mode Display Function Real time mode Shows current strength Counting mode Counts number of gripping actions exceeding a previously set strength limit Ave...

Страница 21: ...l strength Relieve Press Release 2 Change unit kg lb In real mode it is possible to switch from kg to lb by pressing the set key and vice versa During power up the device will return to the mode or un...

Страница 22: ...lay ap pears 2 How to define the strength limit The currently set strength limit is displayed To change press the mode key repeatedly until the de sired strength limit is displayed Ensure that the cap...

Страница 23: ...e as often as possible Each gripping action is acknowledged by an audio sound The number of gripping actions carried out will be shown on screen 4 Start further counting Press the Zero button the zero...

Страница 24: ...ssing the zero key Press mode key repeatedly until avg display appears 2 Determine average strength from two hand grips Carry out first gripping action Strength of first hand grip will be shown Carry...

Страница 25: ...rived from the two hand grips will be calculated and displayed flashing 3 Start further measurements To return to measuring mode press the set key Press the Zero button the zero display disappears Car...

Страница 26: ...xample Example A gripping action achieves a strength of 50 kg Now you are able to determine whether follow up measurements also reach 50 kg 100 or for example only 31 15 5 kg ad justable range 1 100 C...

Страница 27: ...to confirm If a new gripping action shows a strength of less than for in stance 31 15 5 kg the previous max value will be re tained If a new gripping action shows a strength greater than for in stance...

Страница 28: ...fluid from penetrating into device Finish by polishing with dry soft cloth Remove dirt immediately Service main tenance The appliance may only be opened by trained service techni cians who are author...

Страница 29: ...ted For replacing of batteries see chapter 7 Underload set to zero by pressing zero key Overload release device Preload error put minor stress on device during power up EEPROM error switch off and res...

Отзывы: